Cobra
®
Hip Vent’s innovative design helps to provide a safe and effective exhaust venting solution on roofs with
little or no ridge. It’s contractor-friendly and blends into the hip line to allow for a great-looking finished roof.
Stale Air Escapes Through
Cobra
®
Hip Vent (Installed
Under Cap Shingles at the Hips)
Fresh Air
Enters Attic
Through
Intake Vent at
Soffit or Eave
Dual Weather
Fighter
Filter
helps prevent weather,
insect, and even pine needle infiltration
Total Attic
Square Footage
Recommended Minimum
Length Of Cobra
®
Hip Vent
(Feet)
Minimum
Intake Ventilation
(Net Free Area In Sq. In.)
1600 43 387
1900 51 459
2200 59 531
2500 67 603
2800 75 675
3100 83 747
3400 91 819
Cobra
®
Hip Vent
USAGE RECOMMENDATIONS (Based on the 1/300 Attic
Ventilation Rule)
Note: Always have a balanced attic ventilation system. The amount of exhaust ventilation should NEVER exceed the amount of
intake ventilation.
Important: Do NOT install on roof ridge. Cobra
®
Hip Vent must only be installed on hips.