www.sdcsecurity.com Visit our website for more information on our complete product line, new product announcements, pricing, installation instructions and templates. M:\INS\INST-E72 Prog.
Introduction Congratulations, you have just purchased the E72 EntryCheck by SDC, the most advanced stand-alone door lock and access control system on the market today. The lock, designed for easy installation, will provide years of reliable service when properly installed and maintained. This manual is designed to act as a guide through the many features and functions of your upgradeable E72 EntryCheck stand-alone access control system.
Before You Begin KEYPAD INFORMATION The E72 EntryCheck keypad has two special keys: the Terminator and the Programming key. • Terminator - This key functions like the “enter” key on a computer. Once the terminator is pressed, the information entered is saved. The default terminator key for the E72 is “*”. • Programming key - This key is used when entering the programming mode. It is also used by the GGM for lock initialization. The default programming key is the “#” key.
Function 03 Add Resetting Group Schedule the E72 RESETTING THE E72 There may be a time when you need to fully reset your E72 and start over. If you reset the E72, all previous information in the lock memory will be lost. (This includes: users, scheduling, GGM code, E72 ID and lock settings.) Here are the steps to perform a full reset. 1. Remove batteries. 2. Wait approximately 5 minutes to allow capacitor to discharge. 3.
Function 03 Sample FunctionAdd Programming Group Schedule Page Function Name Function Number Function 03 Minimum Group Security Level Needed To Program Function STEPS Group Schedule Level: Master Function Description Function schedules OPEN and CLOSE time/day for an established GROUP of users. This function differs from the Basic Schedule (Func. 02), in that specific GROUPS can be granted access. ENTRIES 1. Enter your UID and PIN. 2. Enter Function Number. 3. Enter Day Code from list below. 4.
Initialize Great Grand Master Function 12 Level: Master Level: Master When the Great Grand Master (GGM) is entered it has the two components that are found in all codes. 1. User ID (UID) 3 to 4 DIGITS 2. Pin Number (PIN) 3 to 6 DIGITS/ALPHA/MULTIPLE KEY DEPRESSIONS 3. UID and PIN have a MAXIMUM TOTAL LENGTH of 9 DIGITS. The length of the GGM’s UID and PIN determine the length of all FUTURE MANAGEMENT and USER CODES.
Set Date / Format Function 13 Function 01 User Maintenance Level: Master Level: Master DATE MUST BE SET PRIOR TO ACTIVATING SCHEDULING. This function SETS the MONTH, DAY, YEAR and DAY OF THE WEEK. This function creates NEW users or deletes EXISTING users. All USERS are REQUIRED to have a GROUP NUMBER (See page iii). GGM Code sets standard length format for all USER CODES. (See page iii.) ENTRIES ENTRIES 1. 2. 3. 4. VISUAL / AUDIO Valid User Code 1.
Basic Schedule Function 02 Function 03 Group Schedule Level: Master Level: Master The BASIC SCHEDULE function is a powerful tool that recognizes those scheduling TIMES that GROUPS have in COMMON. It was designed to give an overall framework to the lock effectively minimizing scheduling under other more cumbersome functions. Ex: All groups have access from 8 am to 5 pm daily. The Basic Schedule is used rather than making separate entries under the group schedule function. The BASIC SCHEDULE (Func.
User Schedule Function 04 Function 05 Schedule Passage Mode Level: Master Level: Master Function schedules OPEN and CLOSE time/day for INDIVIDUAL user. This function is intended to work in conjunction with an existing group schedule. Ex. User “A” belongs to group “25” with access from 8 am-6 pm Mon.-Fri. User “A” also comes in Sat. The User Schedule function allows User “A” to be part of group “25” and have additional access on Saturday. USER SCHEDULE DOES NOT work with BASIC SCHEDULE (Func. 02).
Temporary User Schedule Function 06 Function 07 Change Group Association Level: Master Level: Master Function allows an existing USER to be flagged as a TEMPORARY USER. The TEMPORARY USER will function as a normal user and will have a schedule assigned to them for access rights. The TEMPORARY USER CODE will become invalid once the date range has expired. The TEMPORARY USER CODES are not automatically erased, they remain in memory and can be re-activated.
Change User PIN Function 08 Function 09 Holiday Maintenance Level: User Level: Master Function allows the USER to CHANGE their PIN. The change user PIN function adds overall security to the locks by allowing users to change a compromised PIN at their discretion. Management can prevent PIN changes by not making the user base aware of this functions existence. Function DENYS USERS ACCESS on an observed HOLIDAY.
Deny/Restore Access To Selected Groups Function 10 Function 11 Set Access Level Level: Master Level: Master This function allows RESTRICTED ACCESS to SELECTED USER GROUPS without erasing the group/groups from memory. Once access has been denied to a group/groups then access must be restored using this function. ACCESS is DENIED to ALL GROUPS with access levels LOWER than the ENTERED GROUP.
Clear Memory Function 16 Function 17 Battery Status Check Level: Grand Master Level: Security Guard Group This function will CLEAR the MEMORY of the lock and/or CLEAR ALL SCHEDULES, DATE AND TIME. Function DISPLAYS the BATTERY STATUS using the LED DISPLAY on the keypad as shown below. This makes regular maintenance as easy as possible. Battery status will also be displayed on audit trail. Enter "0" to CLEAR ALL USERS, DATE, TIME, SCHEDULES & FUNCTIONS. (EXCEPT GGM and LOCK ID.
Define Open Time Function 18 Function 30 Manual Passage Mode Level: Master Level: Master This function SETS the time the lock will REMAIN OPEN to allow access. The time INTERVAL may vary between 1-9 SECONDS. Shorter open times help to prevent tailgating. If user opens the door within the set time, access will be granted. Manual Passage Mode is designed to allow free access to the door. There are two types of passage mode: 1. Entered at the door. 2. Schedule Passage Mode. (See Func. 05.) ENTRIES 1.
First Supervisor to Arrive Function 31 Function 32 Pin Only Entry Level: Grand Master Level: Grand Master This function will override the set schedule, denying USERS access until a user with a MINIMUM ACCESS OF SUPERVISOR (02-04) enters their code. After a supervisor enters their code, the schedule will resume from that point. Function allows a SHORTER LENGTH OF CODE to be entered by the user to gain access. When ENABLED, user enters their PIN number FOLLOWED BY “*”.
Double Code Entry Function 33 Function 34 Lock Audio Level: Grand Master Level: Master The function REQUIRES 2 VALID USER CODES to be entered in order to gain access. For higher security restrictions, this function can also be set to require one of the codes to be of Management Level. When set for this option, the first user will enter their code followed by the “*”, the next user will have 5 seconds to enter their code and the “*” before being timed out.
Fail Secure Function 36 Function 37 Set Alternative Terminator Level: Grand Master Level: Grand Master THIS FUNCTION IS ONLY INTENDED FOR USE IN BATTERY POWERED UNITS. In case the low battery warning goes unnoticed, (See Battery Information page iv) and the lock runs out of power, this function ensures that the E72 will fail in a secured state. At that time, a key will be required to open the E72. If this function is not used, the lock will fail in the last state the lock was in.
Upload Lock Information Function 14 Function 15 Download Audit Trail Level: Security Guard Level: Security Guard This function will take the information stored in the IDT and upload and update the E72’s memory. Any changes made at the door via the keypad and not updated in the computer will be lost once the update is complete. For further instruction on the uses of the IDT or software, refer to the IDT instruction manual. Function will DOWNLOAD the E72 audit trail to the IDT.
Lock Upgrade Function 20 Function 35 IR Interrupt Level: Master Level: Grand Master This function is used to upgrade the memory of your E72. Here are the steps. This function PREVENTS IR transmission between the lock and the IDT Upload/Download device for extra security. 1. 2. 3. Obtain the lock serial number. The serial number is printed on the exterior backplate of the E72. Or, using the IDT, the serial number appears on the IDT display, as well as, on the header of the audit trail (Func. 15).
Glossary Military Time Conversion Chart Access code Numeric or alphanumeric data which when correctly entered into a keypad, allows authorized entry into a controlled area without causing an alarm condition. 1:00 a.m..................................0100 2:00 a.m..................................0200 3:00 a.m..................................0300 4:00 a.m..................................0400 5:00 a.m..................................0500 6:00 a.m..................................0600 7:00 a.m...........
Index Add Group Schedule Access, Deny/Restore to Selected Groups, Function 10.........14 Access Level, Set, Function 11 ............................................15 Alternative Terminator, Function 37.......................................25 Audio, Lock, Function 34 ......................................................23 Audit Trail, Download, Function 5..........................................27 Basic Schedule, Function 02...................................................6 Battery Information ........