Service manual

Examples: CALIBRATE:PASSWORD 1234
CAL:PASS 1234
Query Syntax: None
Related Commands: None
4.3.9.3 CAL:POT
This command sets the value for the specified potentiometer. The variable specifies the
potentiometer to be adjusted, 1 thru 5, and the second variable specifies the potentiometer setting,
0 through 255.
Command Syntax: CALibrate:POT <NR1>,<NR1>
Examples: CAIBRATE:POT 1,123
CAL:POT 5,11
Query Syntax: CALibrate:POT? <NR1>
Returned Parameters: <NR1>
Related Commands: None
4.3.9.4 CAL:SCAL:VOLT
This command sets the voltage scale factor for the power supply.
Command Syntax: CALibrate:SCALe:VOLTage <NRf>
Examples: CALIBRATE:SCALE:VOLTAGE 16.0
CAL:SCAL:VOLT 16.0
Query Syntax: CALibrate:SCALe:VOLTage? <>
Returned Parameters: <NR3>
Related Commands: None
4.3.9.5 CAL:SCAL:CURR
This command sets the current scale factor for the power supply.
Command Syntax: CALibrate:SCALe:CURRent <NRf>
61