MS Owners Manual 12/5/03 1:56 PM Page 1 MASTER SPAS OWNER’S MANUAL Welcome To Ultimate Relaxation! Thank you for choosing your new spa built by Master Spas. Please read the entire Owner’s Manual before installing and using your spa. The goal of this manual is to provide you with safety and operational information plus some tips that will help you enjoy your spa to its fullest. At the time of print, this manual is accurate in its information.
MS Owners Manual 12/5/03 1:56 PM Page 2 TABLE OF CONTENTS Important Safety Instructions All Spa Models, Personal Safety ............................................................3-6 Glossary of Spa Terminology ..............................................................7-11 Installation Electrical Installation Requirements ............................................................12 Wiring Schematic ..............................................................................
MS Owners Manual 12/5/03 1:56 PM Page 3 SAFETY INSTRUCTIONS Save These Instructions Included with your new spa is a safety sign.The sign is for you and your guest’s protection and is suitable for outdoor use in wet locations.The sign should be placed in a location visible to all users of the spa. Please take time to point out the physical location of the safety sign and the importance of the safety precautions displayed on the safety sign to all of your guests.
MS Owners Manual 12/5/03 1:56 PM Page 4 SAFETY INSTRUCTIONS Important Safety Instructions When installing and using this electrical equipment, basic safety precautions should be observed including the following: Read And Follow ALL INSTRUCTIONS 1. WARNING. To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. 2. DANGER - RISK OF CHILD DROWNING. Extreme caution must be exercised to prevent unauthorized access by children.
MS Owners Manual 12/5/03 1:56 PM Page 5 SAFETY INSTRUCTIONS Important Safety Instructions (cont.) 8. WARNING - TO REDUCE THE RISK OF INJURY: (A) Always enter and exit a spa slowly. (B) Do not use the spa alone. (C) Before entering the spa, always measure the water temperature with an accurate thermometer.Tolerance of water temperature regulating devices can vary as much as plus/minus 5° F (3° C).
MS Owners Manual 12/5/03 1:56 PM Page 6 SAFETY INSTRUCTIONS Important Safety Instructions (cont.) 9. People with infections, sores or the like should not use the spa.Warm and hot water temperatures may allow the growth of infectious bacteria if not properly disinfected. 10. DANGER - RISK OF ELECTRIC SHOCK. Do not permit any electric appliance, such as a light, telephone, radio or television, within five (5) feet of the spa. Never operate any electrical appliances from inside the spa or while wet. 11.
MS Owners Manual 12/5/03 1:56 PM Page 7 GLOSSARY OF SPA TERMINOLOGY 1. NECK JETS 2. SHOULDER JETS 3. THERAPY JETS 4. MASTER BLASTER FOOT THERAPY JET Your new Master Spa features a variety of jet styles. All jets, regardless of style return the water to the spa. Air is mixed with the water by using the air controls creating a gentle to most vigorous massage. Water flow is adjusted by simply turning the outer face of the jet.
MS Owners Manual 12/5/03 1:56 PM Page 8 GLOSSARY OF SPA TERMINOLOGY 6. CASCADE WATERFALL VALVE - Located on the topside of the spa, this valve adjusts water flow to the cascade waterfall.This feature is available in the LS Series only. Cascade Waterfall Valve 7. AIR CONTROL VALVES - These are located around the top of your spa. You may increase or decrease the force of your jets by opening or closing the air control valves.
MS Owners Manual 12/5/03 1:56 PM Page 9 GLOSSARY OF SPA TERMINOLOGY 9. PERSONAL REMOTE CONTROL - The Legend Series (LS) spas have additional remotes which allow the user to control the jet therapy while remaining in his/her seat. By pressing the control one time, you will activate low speed. Press the pad again for high speed and again to turn it off. Personal Remote Control 10.
MS Owners Manual 12/5/03 1:56 PM Page 10 GLOSSARY OF SPA TERMINOLOGY 13. FILTER LID -Your filter lid will serve to prevent major objects from entering your filter area and possibly damaging your filter elements which are located under the filter lid.These filter elements are designed to remove small debris and oils from your spa water. 14. WEIR GATE - The weir gate is the horizontal door located in front of the filter that traps debris and contains it in the filter area. 15.
MS Owners Manual 12/5/03 1:57 PM Page 11 GLOSSARY OF SPA TERMINOLOGY 19. MAIN PUMP - This produces water flow through the main jets in the spa. The first pump may be operated on two speeds. Low speed will produce efficient water circulation during filtration and gentle jet action. High speed should be used for maximum jet action.
MS Owners Manual 12/5/03 1:57 PM Page 12 ELECTRICAL INSTALLATION REQUIREMENTS HAVE YOUR ELECTRICIAN READ THE FOLLOWING INFORMATION BEFORE INSTALLATION BEGINS Electrical connections made improperly, or the use of wire gauge sizes for incurring power which are too small, may continually blow fuses in the electrical equipment box, may damage the internal electrical controls and components, may be unsafe and in any case will void your warranty.
MS Owners Manual 12/5/03 1:57 PM Page 13 WIRING SCHEMATIC - 240 VOLT SPA HOOK-UP * Actual wiring of GFCI will vary by manufacturer of GFCI.The GFCI shown is a Square D. Improper wiring of GFCI may result in permanent damage to spa system box. Repair / replacement of spa system box is not covered under warranty when damage results from improper wiring.
MS Owners Manual 12/5/03 1:57 PM Page 14 120/240 VOLT SYSTEMS Attn: All electrical connections must be made by a licensed electrician. Failure to do so will void the spa warranty. Optional 120/240 Volt Models Franklin / Revere / Madison Special Note: Franklin, Revere, and Madison Models are pre-wired for 240 Volt installations from the factory. Electrical Requirements for 120 Volt The spa must be connected to a "dedicated" 120 Volt, 15 amp grounded circuit.
MS Owners Manual 12/5/03 1:57 PM Page 15 120/240 VOLT SYSTEMS - Plug-in Instructions Plug-In Instructions for 120V GFCI cord set (optional) Franklin / Revere / Madison 1. Electrical Requirements - Your spa requires a dedicated 120 volt AC 15 AMP electrical outlet and must have a separate, dedicated, grounded circuit having no other appliance connected in the circuit.
MS Owners Manual 12/5/03 1:57 PM Page 16 SITE PREPARATION / GENERAL GUIDELINES Portable spa installation is simple when properly planned.To that end it is important that you read the following information carefully and consult with your Master Spas dealer. 1) Access - The actual dimensions of your new spa will determine the amount of space that is needed in moving the spa from curbside to its final installation area.
MS Owners Manual 12/5/03 1:57 PM Page 17 SITE PREPARATION / GENERAL GUIDELINES GENERAL CONSIDERATIONS FOR OUTDOOR INSTALLATION Again, proper planning will increase your total enjoyment factor with your new spa. Listed below are some additional items to consider when planning your installation.
MS Owners Manual 12/5/03 1:57 PM Page 18 INSTALLATION INSTRUCTIONS 1.) Put spa in final position that allows for access to equipment of spa components. 2.) Remove front side panel (This is the side where the main topside control panel is located) so electrical can be hooked up to the spa system pack. Panels are removed by unscrewing the screws in the corner sections and then lifting up the panels out of the retaining tracks. Removing of Panels 4.) Be sure all pump and heater unions are secure.
MS Owners Manual 12/5/03 1:57 PM Page 19 INSTALLATION INSTRUCTIONS 8.) It may be necessary to bleed air from the motor(s) on your spa if, after start up, your spa pumps do not operate. Due to the nature of water flow and hydro-therapy pumps, please be advised that air locking of pumps may occur. Master Spas has taken measures to reduce the possiblilty of this, but it still may occur, especially after refilling a spa. This is not a service covered under warranty.
MS Owners Manual 12/5/03 1:57 PM Page 20 WATER CHEMISTRY TERMS YOU SHOULD KNOW Before jumping into the Spa Water Maintence, here are some terms to help you. 1. Parts per million, or ppm: This is a form of measurement used in most pool or spa chemical readings. Best described as any one million like items of equal size and make up, next to one unlike item , but of equal size. This would be one part per million. 2.
MS Owners Manual 12/5/03 1:57 PM Page 21 WATER CHEMISTRY TERMS YOU SHOULD KNOW Before jumping into the Spa Water Maintence, here are some terms to help you. 7. Filtration: Filters are necessary to remove particles of dust, dirt, algae, etc. that are continuously entering the water. If the spa is not operated long enough each day for the filter to do a proper job, this puts a burden on the chemicals, causing extra expense.
MS Owners Manual 12/5/03 1:57 PM Page 22 SPA WATER MAINTENANCE Master Spas and Down East Spas * All Down East and Master Spas use the Eco Pur mineral filter(s). This section pertains specifically to maintaining water chemistry in spas that have the Eco Pur mineral filters. SPECIAL NOTE ECO PUR™ water purification system is designed to reduce the use of conventional sanitizers.You will still be required, periodically, based on usage to add a small amount of chlorine to oxidize organic compounds.
MS Owners Manual 12/5/03 1:57 PM Page 23 WATER QUALITY MAINTENANCE START-UP Master Spas and Down East Spas For ECO PUR™ Water Purification System Optional: Fill spa using ECO PUR™ Charcoal Pre-filter. Step 1: During initial filling of the spa with fresh water, add a sequestering agent such as Mineral Clear or Stain and Scale, etc. depending on the brand name. Allow to circulate and filter for at least 12 hours. Step 2: Test water for pH, total Alkalinity, and Calcium hardness. The pH should be 7.
MS Owners Manual 12/5/03 1:57 PM Page 24 THE ADVANTAGES OF ECO PUR™ MINERAL PURIFICATION Master Spas and Down East Spas • Destroys most bacteria, pathogens, algae, and fungi. • Removes many heavy metals like lead and mercury from water. • Removes calcium carbonate and hydrogen sulphide from spa water to protect heaters and equipment from precipitation. • Helps stabilizes the pH and alkalinity of the spa water. • Reduces up to 90% of chemical usage and still provides safe odor-free water.
MS Owners Manual 12/5/03 1:57 PM Page 25 WATER QUALITY MAINTENANCE SCHEDULE-ECO PUR™ Master Spas and Down East Spas BEFORE EACH USE - Add 1 tablespoon of non-chlorine shock or 1/3 tea spoon of Dichlor to spa per 250 gallons. ONCE A WEEK Add 3 Tablespoons of a non-chlorine shock or 1 tea spoon of Dichlor to spa per 250 gallons. 3 TIMES A WEEK Test water using chemical test strips. Adjust sanitizer, pH and Alkalinity accordingly.
MS Owners Manual 12/5/03 1:57 PM Page 26 SPA WATER MAINTENANCE - START-UP Freedom Spas 1. Read the spa owners manual first. 2. Clean the surface with a spa general purpose cleaner or wipe down with a clean wet towel. 3. Begin filling the spa with fresh water. If possible, do not use softened water. 4. When the spa has 2 to 4 inches of water on the bottom, add the recommended amount of a sequestering chemical for that size spa. See the chemical bottle for correct amounts. 5.
MS Owners Manual 12/5/03 1:57 PM Page 27 SPA WATER MAINTENANCE - SCHEDULE Freedom Spas DAY ONE 1. Test and adjust total alkalinity if necessary to between 80 to 150 ppm using the pH / alkalinity increaser or decreaser 1oz. at a time. Wait 15 minutes, retest and adjust if necessary. The pump should be running on high speed during this time with the air controls closed. 2. Test and adjust pH if necessary to within the range of 7.2 to 7.8 using the pH / alkalinity increaser or decreaser 1/2oz. at a time.
MS Owners Manual 12/5/03 1:57 PM Page 28 SPA WATER MAINTENANCE - SCHEDULE Freedom Spas DAY FOUR SKIP DAY FIVE 1. Test and adjust total alkalinity, if necessary, to between 80 and 150 ppm using the pH / alkalinity increaser or decreaser, 1oz. at a time. Wait 15 minutes, retest and adjust if necessary. The pump should be running on high speed during this time with the air controls closed. 2. Test and adjust the pH, if necessary, to within the range of 7.2 to 7.
MS Owners Manual 12/5/03 1:57 PM Page 29 SPA WATER MAINTENANCE TROUBLE-SHOOTING GUIDE Problem Possible Causes How To Fix It Chlorine / Bromine Odor • Excessive Chlorine or bromine levels • Shock water with non-chlorine shock treatment • Low pH • Adjust pH if necessary • Low levels of sanitizer • Shock water with non-chlorine shock treatment or adjust sanitzer levels • pH out of range • Adjust pH level if necessary • Bacteria or algae growth • Adjust sanitizer if necessary • Dirty filters
MS Owners Manual 12/5/03 1:57 PM Page 30 WHY ARE CHEMICALS IMPORTANT IN A SPA 1. Evaporation: As water evaporates, only pure water evaporates, leaving the salts, minerals, metals, and any unused chemicals behind. Adding water adds more salts, minerals, and metals. In time, the water can become saturated with these dissolved solids and can cause stains or scale to form on the walls of the spa or a scale build up inside the equipment.
MS Owners Manual 12/5/03 1:57 PM Page 31 MAINTENANCE RECOMMENDATIONS Your spa requires periodic draining and cleaning to ensure a safe, healthy environment. It is recommended that you clean your spa at least every 180 days. Heavy bather load will require cleaning it more often. TO DRAIN YOUR SPA • See page 9. TO CLEAN YOUR SPA SURFACE • With a soft cloth, wipe down the spa surface with a non-abrasive cleaner such as "409," "Fantastik" or equivalent. Do not use paper towels.
MS Owners Manual 12/5/03 1:57 PM Page 32 WINTERIZING YOUR SPA Many people find they enjoy using their spa more in the winter than any other time. Your spa is designed to be used year round in any type of climate. *However, if you decide you don’t want to use your spa in the winter, you must drain it and follow the winterizing steps listed below: 1.
MS Owners Manual 12/5/03 1:57 PM Page 33 MASTER SPA- SPECIFICATIONS Spa Model Spa Dimensions Electrical Required LSI 557 66"x84"x32" 240 volt 50 amp 230 gallons 535lbs/2375lbs 2 pump 37 LS 650 78"x84"x36" 240volt 50amp 370 gallon 740lbs/3700lb 4 pump 61 LS 700 84"x84"x36" 240 volt 50 amp 410 gallons 820lbs/4100lbs 4 pump 63 LS 750 84"x84"x36" 240 volt 50amp 435 gallons 830lbs/4310lbs 4 pump 63 LS 800 94"x94"x36" 240 volt 50 amp 485 gallons 860lbs/4740lbs 4 pump 63
MS Owners Manual 12/5/03 1:57 PM Page 34 MASTER SPA Indicator Lights Initial Start-up When your spa is first actuated, it will go into Priming mode (after displaying some configuration information). The Priming mode will last for up to 4 minutes and then the spa will begin to heat and maintain the water temperature in the Standard mode. You can exit Priming mode early by pressing "Warm" or "cool". Icon Legend Heat Icon - Indicates different stages of heating.
MS Owners Manual 12/5/03 1:57 PM Page 35 MASTER SPA Mode/Program This button is used to switch between standard, economy, and sleep modes. Press "Mode/Program" to enter mode programming, press "Cool" to cycle through to desired mode (LCD flashed until confirmed), then press "Mode/Program" to confirm selection. Standard mode maintains the desired temperature. Note that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes.
MS Owners Manual 12/5/03 2:04 PM Page 36 MASTER SPA Indicator Lights The top indicator ligh will be lit up if the spa is in its first filter cycle.The next down will be lit if the spa is in the second filter cycle.The third will be lit when the panel is locked.The bottom indicator will be lit when the temperature lock is enabled. Invert Press the "Warm" or "Cool" button, followed by the “Jet 3” button to change the number in the display to read upside down.
MS Owners Manual 12/5/03 2:04 PM Page 37 MASTER SPA Secondary Filter Cycle Programming (cont.) Press "Mode/Prog" to see the "Program", "Filter 2", and "Start Time" icons. Proceed as above. Press "Mode/Prog" to see "Program", "Filter 2", and "End Time" icons. Adjust the time as done above. Pressing "Mode/Prog" will enter the new filter cycle times into the system and display the current water temperature.
MS Owners Manual 12/5/03 2:04 PM Page 38 MASTER SPA Filtration Cycle Programming for LSI557 only The first filter cycle ("day") begins 6 minutes after the spa is powered up. The second filter cycle ("night") begins 12 hours later. Filter duration is programmable for 1 - 12 hours (F1 - F12). The default filter time is 2 hours. To program, press "Warm" or "Cool" then "Jets 1". Press "Warm" or "Cool" to select the filter duration. Press "Jets 1" to select the number of filter cycles.
MS Owners Manual 12/5/03 2:04 PM Page 39 MASTER SPA Diagnostic Messages Message Meaning Action Required No message on display. Power has been cut off to the spa. The control panel will be disabled until power returns. Time of day will be preserved for 30 days on your system. Spa settings are preserved on all systems. OHH "Overheat" - The spa has shut down. One of the sensors has detected 118˚F (approximately 47.8˚C). DO NOT ENTER THE WATER. Remove the spa cover and allow water to cool.
MS Owners Manual 12/5/03 2:04 PM Page 40 MASTER SPA Diagnostic Messages (cont.) Message Meaning Action Required dr Inadequate water detected in heater. Check water level in spa. Refill if necessary. If the water level is okay, make sure the pumps have been primed. Check for a dirty filter and clean if necessary. Press any button to reset. dr4 Inadequate water detected in heater. (Displays on third occurrence of "dr" message.) Spa is shut down. Follow action required for "dr" message.
MS Owners Manual 12/5/03 2:04 PM Page 41 MASTER SPA Periodic Reminder Messages (Press the “Mode” button to reset a displayed reminder) Message Frequency Action Required rPH Every 7 days Test and adjust pH chemical levels per manufacturer’s instructions. rSA Every 7 days Test and adjust sanitizer chemical levels per manufacturer’s instructions. rCL Every 30 days Remove, clean, and reinstall filter per manufacturer’s instructions.
MS Owners Manual 12/5/03 2:04 PM Page 42 DOWN EAST SPA - SPECIFICATIONS Spa Model Spa Dimensions Electrical Required Water Capacity Weight Dry/Full Therapy Pumps Jet Count Concord 66"x84"32" 240 volt 50 amp 220 gallons 410lbs/1510lbs 1 pump 19 Westport 77"x77"x32" 240 volt 50 amp 260 gallons 510lbs/2590lbs 1 pump 28 Bar Harbor 78"x78"x35" 240 volt 50 amp 290 gallons 525lbs/2845lbs 1 pump 19 Providence 78"x84"x36" 240volt 50 amp 370 gallons 605lbs/3565lbs 1 pump 26 Cap
MS Owners Manual 12/5/03 2:04 PM Page 43 DOWN EAST (2 -3 PUMP SYSTEM) East Hampton / Portsmouth / Windsor / Exeter / Cape Cod (2 Pump System Plus Optional Circ. Pump Feature) East Hampton SE / Portsmouth SE / Windsor SE / Exeter SE/ Cape Cod SE (3 Pump System) Initial Start-up When your spa is first activated, it will go into priming mode (after displaying some configuration information).
MS Owners Manual 12/5/03 2:04 PM Page 44 DOWN EAST (2 -3 PUMP SYSTEM) Mode This button is used to switch between standard, economy, and sleep modes. Press "Mode" to enter mode programming, press "Cool" to cycle through to desired mode (LCD flashes until confirmed), then press "Mode" to confirm selection. Standard mode maintains the desired temperature. Note that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes.
MS Owners Manual 12/5/03 2:04 PM Page 45 DOWN EAST (2 -3 PUMP SYSTEM) Jets 2 Press the "Jet 2" button once to turn pump 2 on or off. If left running, the pump will turn off after 15 minutes. * Jets 3 Note: For SE models only. Press the "Jets 3" button once to turn pump 3 on or off. If left running, the pump will turn off after 15 minutes. * Light Depending upon how your spa is equipped and configured, the "Light" button will operate in one of the following ways: 1.
MS Owners Manual 12/5/03 2:04 PM Page 46 DOWN EAST (2 -3 PUMP SYSTEM) Clean-up Cycle When the pump is turned on by a button, a clean-up cycle begins 30 minutes after the pump is turned off or times out. The pump and the ozone generator will run for one hour. Ozone (optional) On most systems, the ozone generator (if installed) runs during filter cycles (except when pump 1 is operating at high speed on a non-circ system) and during clean-up cycles.
MS Owners Manual 12/5/03 2:04 PM Page 47 DOWN EAST (2 -3 PUMP SYSTEM) Diagnostic Messages Message Meaning Action Required No message on display. Power has been cut off to the spa. The control panel will be disabled until power returns. Time of day will be preserved for 30 days with a battery back-up on. EL2000 and EL1000 systems reset the time of day on each power-up. Spa settings are preserved on all systems. OHH "Overheat" - The spa has shut down. On some systems, an alarm may sound.
MS Owners Manual 12/5/03 2:04 PM Page 48 DOWN EAST (2 -3 PUMP SYSTEM) Diagnostic Messages (cont.) Message Meaning Action Required dr Inadequate water detected in heater. Check water level in spa. Refill if necessary. If the water level is okay, make sure the pumps have been primed. Check for a dirty filter and clean if necessary. Press any button to reset. dr4 Inadequate water detected in heater. (Displays on third occurrence of "dr" message.) Spa is shut down.
MS Owners Manual 12/5/03 2:04 PM Page 49 DOWN EAST (2 -3 PUMP SYSTEM) Periodic Reminder Messages (Press the “Mode” button to reset a displayed reminder) Message Frequency Action Required rPH Every 7 days Test and adjust pH chemical levels per manufacturer’s instructions. rSA Every 7 days Test and adjust sanitizer chemical levels per manufacturer’s instructions. rCL Every 30 days Remove, clean, and reinstall filter per manufacturer’s instructions.
MS Owners Manual 12/5/03 2:05 PM Page 50 FREEDOM SPA- SPECIFICATIONS Spa Model Spa Dimensions Electrical Required Franklin 59"x78"x32" 120/240 volt 15/50 amp 160 gallons 450lbs/1730lbs 1 pump 10 Revere 76"x76"x33" 120/240 volt 15/50 amp 200 gallons 490lbs/2090lbs 1 pump 19 Madison 77"x77"x32" 120/240 volt 15/50 amp 230 gallons 495lbs/2335lbs 1 pump 20 Washington 84"x84"x36" 240 volt 50 amp 290 gallons 660lbs/2980lbs 1 pump 32 Jefferson 91"x94"x 36" 240 volt 50amp 480 g
MS Owners Manual 12/5/03 2:05 PM Page 51 DOWN EAST AND FREEDOM - SINGLE PUMP SYSTEM Initial Start-up When your spa is first energized, it will go into Priming mode, indicated by Pr. The Priming mode will last for less than 5 minutes and then the spa will begin to heat the spa and maintain the water temperature in the Standard mode. Temp Set (80˚F - 104˚F / 26.0˚C - 40.0˚C) The factory preset temperature is set at 100˚F/ 37.5˚C. The last measured temperature is constantly displayed on the LCD.
MS Owners Manual 12/5/03 2:05 PM Page 52 DOWN EAST AND FREEDOM - SINGLE PUMP SYSTEM Mode Mode is changed by pressing the "Temp" button, then pressing the "Light" button. Standard Mode is programmed to maintain the desired temperature. Note that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes. "St" will be displayed momentarily when you switch into Standard Mode. Economy Mode heats the spa to set temperature only during filter cycles.
MS Owners Manual 12/5/03 2:05 PM Page 53 DOWN EAST AND FREEDOM SINGLE PUMP SYSTEM Diagnostic Messages Message Meaning Action Required No message on display. Power has been cut off to the spa. The control panel will be disabled until power returns. Spa settings are preserved until next power up. __ Temperature unknown. After the pump has been running for 2 minutes, the temperature will be displayed. HH "Overheat" - The spa has shut down. One of the sensors has detected 118˚F (approximately 47.
MS Owners Manual 12/5/03 2:05 PM Page 54 MAX STEREO SYSTEM Available on select Master Spa and Down East Models WARNING: Never remain in your spa longer than 15 minutes per session when the water temperature is above 98˚ F. If you wish to spend more time in your spa, whether enjoying music, watching tv, or just lounging, be sure to keep the spa water at or below body temperature (98.6˚ F). * Please refer to the Sony Stereo Owner’s Manual for specific operations.
MS Owners Manual 12/5/03 2:05 PM Page 55 MAX STEREO SYSTEM - (continued) Available on select Master Spa and Down East Models Note: Speakers should be in the down position before covering your spa. Failure to do so will result in damage not covered under the warranty. Note: UV rays may interfere with the operation of the Sony remote. The Sony Stereo is shipped with the detachable stereo face in the spa’s luggage pack.The stereo face must be inserted to operate any stereo funtions.
MS Owners Manual 12/5/03 2:05 PM Page 56 FLAT SCREEN TV (FST) / STEREO SYSTEMS STS, LS 750 FST, and LSX 1050 Note: We have included the stereo and DVD owner’s manual with your spa. This should be read to see the specific operation of these components. Note: Do not place wet DVD’s or CD’s into the players at any time. Resulting damage will not be covered under warranty.
MS Owners Manual 12/5/03 2:05 PM Page 57 FLAT SCREEN TV (FST) / STEREO SYSTEMS (continued) STS, LS 750 FST, and LSX 1050 Your FST spa (and any spa with a stereo) comes equipped with a locking, water resistant enclosure for the DVD player and stereo. We have installed an F-81 television coaxial cable connector located under the front panel for your convenience.This can be utilized if you wish to add a cable connection or satellite connection to your FST.
MS Owners Manual 12/5/03 2:05 PM Page 58 DOLPHIN REMOTE All FST spas come with a Dolphin Remote Control.This remote operates off an RF frequency and controls TV, DVD, and Stereo functions. It will also operate the therapy pumps and the light (using the “light” button).The blower, fiber, and opt. 2 buttons are not used. Opt. 1 will cause the TV/speakers to lift or lower. The Dolphin Remote has replaceable batteries.
MS Owners Manual 12/5/03 2:05 PM Page 59 DOLPHIN REMOTE Power Key: (A) Turns the power on and off to the TV and DVD. NOTE: To engage power to the Sony CD player, use the TV/VID button in the CD device mode. Volume Keys: (B) Adjusts the volume in the selected device mode. A Channel Keys: (C) In the CD mode, these keys will scan CD tracks or scan radio stations. In TV mode, it will scroll through the channels. Spa Function Keys: (D) Will control the pump 1, 2, 3 and the light operations. Opt.
MS Owners Manual 12/5/03 2:05 PM Page 60 DOLPHIN REMOTE Setup Key: (F) Use this key to program device codes and sequences (see page 61).Your Dolphin Remote has been preprogrammed at the factory for all components included.When the batteries are replaced, these components need to be reprogrammed. Device Mode Keys: (G) Select unit to control by pressing device key once. The TV, DVD, CD, and (if applicable) CBL/SAT buttons are used on the FST spa.
MS Owners Manual 12/5/03 2:05 PM Page 61 DOLPHIN REMOTE Programming Device Codes: NOTE:Your remote has been preprogrammed at the factory for all components.When the batteries are replaced, these components need to be reprogrammed. 1.) Select Device: The LED will blink once to confirm. Manually engage power to selected device. 4 2 1 2.) Press and Hold the "Setup" key: The LED will blink once, then will blink twice to continue. 3.
MS Owners Manual 12/5/03 2:05 PM Page 62 DOLPHIN REMOTE SYSTEM PROMPT To View TV Channels: Engage Power To Monitor 1) Select Device Mode (TV). (G) 2) Press Power. (A) 3) Select Guide. (H) 4) Select desired channel. (C or I) Engage Power to CD Player 1) Select Device Mode (CD). (G) 2) Press TV / Vid to engage power. (E) 3) Press TV / Vid to select CD2. (E) CD2 will prompt TV audio. A G H NOTE on Initial Start Up to detect incoming channel reception. 1) Select TV device mode.
MS Owners Manual 12/5/03 2:05 PM Page 63 DOLPHIN REMOTE DEVICE MODES / FEATURE KEYS CD Device Mode (E) TV / Vid = Source - Aux / Power (A) This key will engage power to the unit, as well as scroll between radio / CD mode. (B) Vol Up / Down = Volume The main volume for the theater system is controlled through the CD Device Mode. (C) CHN Up / Down = Scan / Seek These keys will scan / seek radio station presets and CD audio tracks. (A) Power = Off This key will disengage power to the unit.
MS Owners Manual 12/5/03 2:06 PM Page 64 DOLPHIN REMOTE TV DEVICE MODE (H) Guide = TV / Catv This key will prompt TV to antenna or cable feed. (E) TV / Vid = DVD / Video / Aux This key will prompt monitor to DVD channel. (A) Power = On / Off This key will engage / disengage power to unit. (B) Vol Up / Down = Level These keys will adjust volume level from TV. An optimum level for the TV is 35 - 40. (I) Numeric Keypad = Manual These keys will direct prompt individual TV Channels.
MS Owners Manual 12/5/03 2:06 PM Page 65 SPA TROUBLE SHOOTING GUIDE NOTHING ON THE SPA OPERATES1.) Check the control panel display for any messages. If there is a message, refer to the diagnostic section on that model spa.There you will find the meaning of the message and what action is to be taken. 2.) If there is no message on your control panel, check and reset the GFCI and house breaker. *The GFCI should be located in a weather proof box close to the spa, but no closer than 5 ft.
MS Owners Manual 12/5/03 2:06 PM Page 66 SPA TROUBLE SHOOTING GUIDE SPA NOT HEATING * If the spas heater has failed, the majority of the time it will trip the GFCI breaker. If the spa is not heating and has not tripped the breaker, please follow these steps: 1.) Check the control panel for diagnostic messages. Refer to your spa models diagnostic message area in previous sections. Follow steps to alleviate message. 2.) Check water set temperature at control panel. 3.) Check for dirty filters.
MS Owners Manual 12/5/03 2:06 PM Page 67 REGULAR MAINTENANCE PROCEDURES Note: These are areas that will require the spa owner to perform routine maintenance.These are not areas covered under the warranty of the spa. CLEANING JETS The majority of jets in your spa can individually be turned on/off. If any of these jets become hard to turn, it will be necessary to remove the jet to clean it as grit/sand and mineral deposit may be present.
MS Owners Manual 12/5/03 2:06 PM Page 68 REGULAR MAINTENANCE PROCEDURES CLEANING DIVERTER VALVES - cont. Turn the cap piece counter clockwise. It may be necessary to put a clean rag over the cap and turn it with a wrench. Once loose, the cap and handle can be pulled up out of the white plumbing fitting. Wipe down the internal piece that attaches to the cap and handle. Soak the cap and handle in white vinegar. The white plumbing fitting should also be wiped down.
MS Owners Manual 12/5/03 2:06 PM Page 69 REGULAR MAINTENANCE PROCEDURES CIRC PUMP DISCHARGE FITTING NEEDS TO BE CLEANED The circ pump discharge screen should be removed and cleaned if your spa is equipped with a circ pump.This screen can get clogged up due to mineral deposit or debris. It should be cleaned at least once every 180 days or when the spa is drained. Directions to remove the screen: With the power to the spa off, remove the two screws holding the screen in place.
MS Owners Manual 12/5/03 2:06 PM Page 70 REGULAR MAINTENANCE PROCEDURES CARE OF YOUR SPA COVER Always cover your spa when not in use.This will greatly reduce energy consumption and will cause spa water to heat more rapidly.Water loss and chemical usage will also be reduced. • Be sure to lock down all straps on cover after each use to prevent wind damage. • Do not allow spa to sit uncovered in direct sunlight.This may cause damage to exposed surfaces of spa and possible discoloration of spa fittings.
MS Owners Manual 12/5/03 2:06 PM Page 71 SPA CARE AND MAINTENANCE RECORD DATE DATE DATE DATE DATE DATE DATE DATE Drain & Clean Spa Clean Filter Cartridges Change ECO PUR™ Element Every 180 Days Soak Filter Cartridges in Solution Test GFCI Clean and Condition Spa Cover and Cabinet Miscellaneous Service America’s Leader In Luxury 71 M A S T E R S PA S
MS Owners Manual 12/5/03 2:06 PM Page 72 SPA CARE AND MAINTENANCE RECORD DATE DATE DATE DATE DATE DATE America’s Leader In Luxury DATE 72 DATE DATE DATE DATE DATE M A S T E R DATE S PA S