Line Voltage
The specified voltage within 10%± is required for proper operation of the propulsion GFCI and all
connected equipment. Should an auto transformer (also know as a buck-boost transformer) be
required, we recommend the following model:
Manufacturer: Dongan • Model: 80-M040 • Wire Configuration: See “Technical Drawings” section
Serviceability and Equipment Access
The design information relating to structural, electrical, architectural, and plumbing design should
be adhered to so as to insure serviceability of the spa in the future. Non compliance with these
requirements could result in the warranty being voided.
PREPARATION OF THE SPA SITE
The owner will be responsible for all site preparation before and after delivery of the spa. All utili-
ties (water, sanitary, electrical, and etc.), mechanical pit, and applicable spa area structures must
be designed and installed by the owner. For information concerning details of these requirements,
consult the technical specifications included in this manual.
SPECIFICATIONS FOR SPA ROOM AREA
If installed indoors, the recommendation for the area in which the spa is contained is at least 3 feet
of separation between outer edge of spa and interior wall around perimeter and 8 feet high. This
is to allow adequate room for installation and proper deck space in the spa area. Extra space for
shower, storage cabinets, dehumidifiers, changing areas, and showers should be integrated into
these plans. Room dimensions may vary depending on requirements of the local and state regula-
tory authority having jurisdiction.
Temperature control and proper air handling (which should include humidity control) in the spa
room must be integrated into the room design to maintain a comfortable and safe environment for
the room occupants. Spa rooms are normally kept at 85 degrees Fahrenheit and spa water tempera-
tures are typically kept below 93 degrees Fahrenheit. This helps keep the differential between the
spa and room temperatures to a minimum.
Minimum Component Requirements (Installed components shall be NSF-50 certified for pool and spa use)
Filter Pump* Max. 1.5HP @ SF 1.10 Shall not exceed max. filter specification, or 251 GPM
Jet Pump 1* Shall not exceed 251 GPM Recommended 1.5 HP @ 1.10 SF
Jet Pump 2* Shall not exceed 251 GPM Recommended 2.0 HP @ 1.10 SF
Chlorinator .5 lbs./day/1,000 gallons (level 3) Local/State codes may vary
Filter 200 sq. ft. Loading rate .375 GPM / sq. ft.
Recommended Components
Component Description Master Spas Part Number
Filter Pump Waterway Champion 1.5 HP Pump X320521
Jet Pump 1 Waterway Champion 2.0 HP Pump X320522
Jet Pump 2 Waterway Champion 1.5 HP Pump X320521
Chlorinator (level 3) Waterway Clear Water Tablet Feeder X268518
Filter Waterway ProClean 200 SF Filter X268516
Optional Skid Pack* Complete Skid Pack w/all components X620690
* Installer shall confirm that the pumps are not capable of exceeding the maximum flow rate specified on the installed suctions (251
GPM). This shall be confirmed by either using recommended components, or testing the system prior to completion of install.
All pumps and filtration systems components shall meet the requirements of: NSF/ANSI 50 and/or ANSI/UL 1081
*Skid pack comes with filter pump, jet pump 1, jet pump 2, chlorinator, filter, and plastic mounting plates.
Recommended components will satisfy the requirements of NSF-50 and most local and state codes. Should a local or state code require
a more restrictive component, the local code shall take priority over these recommended components unless code presents an unsafe
configuration such as a pump that exceeds the flow specifications of the installed suction.