07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 1 O w n e r ’s M a n u a l 2007
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 2 MASTER SPAS OWNER’S MANUAL Welcome To Ultimate Relaxation! Thank you for choosing your new spa built by Master Spas. Please read the entire Owner’s Manual before installing and using your spa. The goal of this manual is to provide you with safety and operational information plus some tips that will help you enjoy your spa to its fullest. At the time of print, this manual is accurate in its information.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 3 TABLE OF CONTENTS Important Safety Instructions All Spa Models, Personal Safety ............................................................................3-6 Glossary of Spa Terminology ..............................................................................7-11 Installation Electrical Installation Requirements ..............................................................................12 Wiring Schematic ................................
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 4 SAFETY INSTRUCTIONS Save These Instructions Included with your new spa is a safety sign.The sign is for you and your guest’s protection and is suitable for outdoor use in wet locations.The sign should be placed in a location visible to all users of the spa. Please take time to point out the physical location of the safety sign and the importance of the safety precautions displayed on the safety sign to all of your guests.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 5 SAFETY INSTRUCTIONS Important Safety Instructions When installing and using this electrical equipment, basic safety precautions should be observed including the following: Read And Follow ALL INSTRUCTIONS 1. WARNING. To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. 2. DANGER - RISK OF CHILD DROWNING.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 6 SAFETY INSTRUCTIONS Important Safety Instructions (cont.) 8. WARNING - TO REDUCE THE RISK OF INJURY: (A) Always enter and exit a spa slowly. (B) Do not use the spa alone. (C) Before entering the spa, always measure the water temperature with an accurate thermometer.Tolerance of water temperature regulating devices can vary as much as plus/minus 5° F (3° C).
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 7 SAFETY INSTRUCTIONS Important Safety Instructions (cont.) 9. People with infections, sores or the like should not use the spa.Warm and hot water temperatures may allow the growth of infectious bacteria if not properly disinfected. 10. DANGER - RISK OF ELECTRIC SHOCK. Do not permit any electric appliance, such as a light, telephone, radio or television, within five (5) feet of the spa.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 8 GLOSSARY OF SPA TERMINOLOGY 1. NECK JETS 2. SHOULDER JETS 3. THERAPY JETS 4. MASTER BLASTER FOOT THERAPY JET Your new Master Spa features a variety of jet styles. All jets, regardless of style return the water to the spa. Air is mixed with the water by using the air controls creating a gentle to most vigorous massage. Water flow is adjusted by simply turning the outer face of the jet.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 9 GLOSSARY OF SPA TERMINOLOGY 6. CASCADE WATERFALL VALVE - Located on the topside of the spa, this valve adjusts water flow to the cascade waterfall.This feature is available on the Legend Series only. Cascade Waterfall Valve 7. AIR CONTROL VALVES - These are located around the top of your spa. You may increase or decrease the force of your jets by opening or closing the air control valves.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 10 GLOSSARY OF SPA TERMINOLOGY 9. PERSONAL REMOTE CONTROL - The Legend Series (LS) spas have additional remotes which allow the user to control the jet therapy while remaining in his/her seat (if applicable). By pressing the control one time, you will activate low speed. Press the pad again for high speed and again to turn it off. Personal Remote Control 10.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 11 GLOSSARY OF SPA TERMINOLOGY 13. FILTER LID -Your filter lid will serve to prevent major objects from entering your filter area and possibly damaging your filter elements which are located under the filter lid.These filter elements are designed to remove small debris and oils from your spa water. 14. WEIR GATE - The weir gate is the horizontal door located in front of the filters that trap debris in the filter area. 15.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 12 GLOSSARY OF SPA TERMINOLOGY 19. MAIN PUMP - This produces water flow through the main jets in the spa. The first pump may be operated on two speeds. Low speed will produce efficient water circulation during filtration and gentle jet action. High speed should be used for maximum jet action.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 13 ELECTRICAL INSTALLATION REQUIREMENTS ELECTRICAL INSTALLATION REQUIREMENTS HAVE YOUR ELECTRICIAN READ THE FOLLOWING INFORMATION BEFORE INSTALLATION BEGINS Electrical connections made improperly, or th e use of wire gauge sizes for incurring power which are too small, may continuallyblow fuses in the electrical equipment box, may damage the internal electrical controls and components, may be unsafe and in any case will void your warranty.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 14 WIRING SCHEMATIC - 240 VOLT SPA HOOK-UP Balboa Instruments G.F.C.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 15 SITE PREPARATION / GENERAL GUIDELINES Portable spa installation is simple when properly planned.To that end, it is important that you read the following information carefully and consult with your Master Spas dealer. 1) Access - The actual dimensions of your new spa will determine the amount of space that is needed in moving the spa from curbside to its final installation area.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 16 SITE PREPARATION / GENERAL GUIDELINES GENERAL CONSIDERATIONS FOR OUTDOOR INSTALLATION Again, proper planning will increase your total enjoyment factor with your new spa. Listed below are some additional items to consider when planning your installation.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 17 INSTALLATION INSTRUCTIONS 1.) Put spa in final position that allows for access to equipment and spa components. 2.) Remove front side panel (This is the side where the main topside control panel is located) so electrical can be hooked up to the spa system pack. Panels are removed by unscrewing the screws in the corner sections and then lifting up the panels out of the retaining tracks. Removing of Panels 4.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 18 INSTALLATION INSTRUCTIONS 8.) It may be necessary to bleed air from the motor(s) on your spa if, after start up, your spa pumps do not operate. Due to the nature of water flow and hydro-therapy pumps, please be advised that air locking of pumps may occur. Master Spas has taken measures to reduce the possibility of this, but it still may occur, especially after refilling a spa. This is not a service covered under warranty.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 19 WATER CHEMISTRY TERMS YOU SHOULD KNOW Before jumping into the Spa Water Maintenance, here are some terms to help you. 1. Parts per million, or ppm: This is a form of measurement used in most pool or spa chemical readings. Best described as any one million like items of equal size and make up, next to one unlike item , but of equal size. This would be one part per million. 2.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 20 WATER CHEMISTRY TERMS YOU SHOULD KNOW Before jumping into the Spa Water Maintenance, here are some terms to help you. 7. Filtration: Filters are necessary to remove particles of dust, dirt, algae, etc. that are continuously entering the water. If the spa is not operated long enough each day for the filter to do a proper job, this puts a burden on the chemicals, causing extra expense.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 21 SPA WATER MAINTENANCE Legend Series Spas and Down East Spas * All Down East and Legend Series Spas use the Eco Pur mineral filter(s).This section pertains specifically to maintaining water chemistry in spas that have the Eco Pur mineral filters. SPECIAL NOTE ECO PUR™ water purification system is designed to reduce the use of conventional sanitizers.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 22 WATER QUALITY MAINTENANCE START-UP Legend Series Spas and Down East Spas For ECO PUR™ Water Purification System Optional: Fill your spa using a Pre-filter, which can be obtained from your local dealer. Step 1: During initial filling of the spa with fresh water, add a sequestering agent such as Mineral Clear or Stain and Scale, etc. depending on the brand name. Allow to circulate and filter for at least 12 hours.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 23 THE ADVANTAGES OF ECO PUR™ MINERAL PURIFICATION Legend Series Spas and Down East Spas • Destroys most bacteria, pathogens, algae, and fungi. • Removes many heavy metals like lead and mercury from water. • Removes calcium carbonate and hydrogen sulphide from spa water to protect heaters and equipment from precipitation. • Helps stabilize the pH and alkalinity of the spa water.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 24 WATER QUALITY MAINTENANCE SCHEDULE-ECO PUR™ Legend Series Spas and Down East Spas BEFORE EACH USE - Check spa water with a test strip for proper sanitation levels and adjust accordingly to the proper levels. ONCE A WEEK Add 3 Tablespoons of a non-chlorine shock or 1 tea spoon of Dichlor to spa per 250 gallons. 3 TIMES A WEEK Test water using chemical test strips. Adjust sanitizer, pH and Alkalinity accordingly.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 25 SPA WATER MAINTENANCE - START-UP Freedom Spas (For Spas without Eco Pur™ Mineral Purification System) 1. Read the spa owners manual first. 2. Clean the surface with a spa general purpose cleaner or wipe down with a clean wet towel. 3. Begin filling the spa with fresh water. If possible, do not use softened water. 4. When the spa has 2 to 4 inches of water on the bottom, add the recommended amount of a sequestering chemical for that size spa.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 26 SPA WATER MAINTENANCE - START-UP Freedom Spas (For Spas without Eco Pur™ Mineral Purification System) DAY ONE 1. Test and adjust total alkalinity if necessary to between 80 to 150 ppm using the pH / alkalinity increaser or decreaser 1oz. at a time. Wait 15 minutes, retest and adjust if necessary. The pump should be running on high speed during this time with the air controls closed. 2. Test and adjust pH, if necessary, to within the range of 7.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 27 SPA WATER MAINTENANCE - START-UP Freedom Spas (For Spas without Eco Pur™ Mineral Purification System) DAY FOUR SKIP DAY FIVE 1. Test and adjust total alkalinity, if necessary, to between 80 and 150 ppm using the pH / alkalinity increaser or decreaser, 1oz. at a time. Wait 15 minutes, retest and adjust if necessary. The pump should be running on high speed during this time with the air controls closed. 2.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 28 SPA WATER MAINTENANCE TROUBLE-SHOOTING GUIDE Problem Possible Causes How To Fix It Chlorine / Bromine Odor • Excessive Chlorine or bromine levels • Shock water with non-chlorine shock treatment • Low pH • Adjust pH if necessary • Low levels of sanitizer • Shock water with non-chlorine shock treatment or adjust sanitizer levels • pH out of range • Adjust pH level if necessary • Bacteria or algae growth • Adjust sanitizer if necessary
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 29 WHY ARE CHEMICALS IMPORTANT IN A SPA 1. Evaporation: As water evaporates, only pure water evaporates, leaving the salts, minerals, metals, and any unused chemicals behind. Adding water adds more salts, minerals, and metals. In time, the water can become saturated with these dissolved solids and can cause stains or scale to form on the walls of the spa or a scale build up inside the equipment.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 30 MAINTENANCE RECOMMENDATIONS Your spa requires periodic draining and cleaning to ensure a safe, healthy environment. It is recommended that you clean your spa at least every 180 days. Heavy bather load will require cleaning it more often. TO DRAIN YOUR SPA • See page 9. TO CLEAN YOUR SPA SURFACE • With a soft cloth, wipe down the spa surface with a non-abrasive spa surface cleaner that may be purchased through your local spa dealer.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 31 WINTERIZING YOUR SPA Many people find they enjoy using their spa more in the winter than any other time. Your spa is designed to be used year round in any type of climate. *However, if you decide you don’t want to use your spa in the winter, you must drain it and follow the winterizing steps listed below: 1.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 32 MASTER SPA - LEGEND SERIES - SPECIFICATIONS Spa Model Spa Dimensions Electrical Required Number of Pumps Jet Count LSI 557 66"x84"x32" 240 volt 50 amp 230 gallons 535lbs/2451lbs 3 pump 37 LS 700 84"x84"x36" 240 volt 50 amp 410 gallons 820lbs/4235lbs 4 pump 76 LS 750 84"x84"x36" 240 volt 50amp 435 gallons 830lbs/4454lbs 4 pump 68 LS 800 94"x94"x36" 240 volt 50 amp 485 gallons 860lbs/4900lbs 4 pump 76 LS800STS 94"
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 33 MASTER SPA - LEGEND SERIES Your Master Spas MS5000 is an EL5000 system. Please reference the sections in this document that apply to the EL5000. Note regarding the EL and GL systems: Mach 2.0 EL and GL systems function identically, but conform to different International requirements. This reference card will refer to EL systems for the sake of simplicity, but the information given applies to both EL and GL products.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 34 MASTER SPA - LEGEND SERIES Setting the Time Once the spa has been properly connected the first time, notice the "Time" icon appearing on the screen. Press Then Select the hour by pressing Press or (Each press changes the time by 1 hour) to enter. Select minutes by pressing or (Each press changes the time by 1 hour) Press to exit the time setting procedure and enter the optional filter cycle programming. Press to exit programming.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 35 MASTER SPA - LEGEND SERIES Optional Filter Cycle Programming (cont.) Press “Program/Mode” to see the “PROGRAM,” “FILTER 2” and “END TIME” icons. Adjust the time as done above. Pressing “Program/Mode” will enter the new filter cycle times into the system and display the current water temperature. Pressing “Time” at any time during this programming sequence will save the values entered up to that point and exit programming.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 36 MASTER SPA - LEGEND SERIES Pressing "Jets 1" while in Economy mode puts the spa in Standard-In-Economy mode, which operates the same as Standard Mode, then reverts to Economy Mode automatically after 1 hour. During this time, a press of the "Program/Mode" button will revert to Economy Mode immediately. Sleep Mode heats the spa to within 20˚F (11˚C) of the set temperature only during filter cycles.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 37 MASTER SPA - LEGEND SERIES Light Press the “Light” button to turn the light on and off. If left on, the light automatically turns off after 4 hours. L.E.D. Light Press the "Light" button to turn the light on and off. If you wish to change the "function" of the lights, turn the lights off, then on within 5 seconds.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 38 MASTER SPA - LEGEND SERIES Clean-up Cycle (optional) When the pump is turned on by a button press, a clean-up cycle begins 30 minutes after the pump is turned off or times out.The pump and the ozone generator will run for one hour. Ozone On most systems, the ozone generator (if installed) runs during filter cycles (except when pump 1 is operating at high speed on a a non-circ system) and during clean-up cycles.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 39 MASTER SPA Diagnostic Messages Action Required Message Meaning No message on display. Power has been cut off to the spa. The control panel will be disabled until power returns. Time of day will be preserved for 30 days on your system. Spa settings are preserved on all systems. "Overheat" - The spa has shut down. On some systems, an alarm may sound. One of the sensors has detected 118˚F (approximately 47.8˚C) at the heater.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 40 MASTER SPA Diagnostic Messages (cont.) Message Meaning Action Required See the M-7 Installation Instruction Manual for complete instructions on Power-up and Pump Priming. The Priming mode will last for up to 4 minutes and then the spa will begin to heat and maintain the water temperature in the Standard mode. When your spa is first actuated, it will go into Priming mode.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 41 MASTER SPA - LEGEND SERIES - LSI 557/LSX 557 Initial Start-up When your spa is first actuated, it will go into Priming mode, indicated by “Pr.” The Priming mode will last for less than 5 minutes (press “Warm” or “Cool” to skip Priming Mode) and then the spa will begin to heat the spa and maintain the water temperature in the Standard mode. This system is equipped with a 24-hour circ pump.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 42 MASTER SPA - LEGEND SERIES - LSI 557/LSX 557 Light Press the “Light” button to turn the light on and off. If left on, the light automatically turns off after 4 hours. L.E.D. Light Press the "Light" button to turn the light on and off. If you wish to change the "function" of the lights, turn the lights off, then on within 5 seconds.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 43 MASTER SPA - LEGEND SERIES - LSI 557/LSX 557 Diagnostic Messages Action Required Message Meaning No message on display. Power has been cut off to the spa. The control panel will be disabled until power returns. Time of day will be preserved for 30 days on your system. Spa settings are preserved on all systems. Temperature is unknown. After the pump has been running for 2 minutes, the temperature will be displayed.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 44 MASTER SPA - LEGEND SERIES - LSI 557/LSX 557 Diagnostic Messages (cont.) Action Required Message Meaning Possible inadequate water, poor flow, or air bubbles are detected in the heater. Spa is shut down for 15 minutes. Check water level in spa. Refill if necessary. If the water level is okay, make sure the pumps have been primed. Press any button to reset, or this message will automatically reset within 15 minutes.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 45 DOWN EAST SPA - SPECIFICATIONS Spa Model Spa Dimensions Electrical Required Mystic 82"x60"30" 240 volt 50 amp 185 gallons 450lbs/2590lbs 2 pump 24 Cape Cod 3 84"x84"x36" 240 volt 50 amp 425 gallons 715lbs/4115lbs 3 pump 58 Cape Cod SE 84"x84"x36" 240 volt 50amp 425 gallons 745lbs/4145lbs 4 pump 73 Exeter 3 84"x84"x36" 240 volt 50 amp 410 gallons 705lbs/3985lbs 3 pump 57 Exeter SE 84"x84"x36" 240 volt 50 amp 410 g
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 46 DOWN EAST (3 -4 PUMP SYSTEMS) Initial Start-up When your spa is first actuated, it will go into Priming mode, indicated by "Pr." Be sure the pumps and heating system are free of air by cycling the pumps on and off with the spa-side panel buttons.The spa will not heat during priming mode, allowing time to verify all air is purged from the heater.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 47 DOWN EAST (3 -4 PUMP SYSTEMS) Jets 1 Touch the "Jets 1" button once to turn pump 1 on or off. If left running, and the pump will automatically turn off after 15 minutes. Jets 2 Touch the "Jets 2" button once to turn pump 2 on or off. If left running, pump 2 will automatically turn off after 15 minutes. Jets 3 (if equipped) This button is used to turn the pump 3 on and off. If left on, this device automatically turns off after 15 minutes.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 48 DOWN EAST (3 -4 PUMP SYSTEMS) Filtration The circulation pump runs constantly for filtration and the ozone generator (if installed) will be enabled. Freeze Protection If the temperature sensors detect a drop to below 44°F/6.7°C within the heater, the pump(s) will automatically activate to provide freeze protection. The equipment stays on until 4 minutes after the sensors detect that the spa temperature has risen to 45°F/7.2°C or higher.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 49 DOWN EAST (3 -4 PUMP SYSTEMS) Diagnostic Messages Action Required Message Meaning No message on display. Power has been cut off to the spa. The control panel will be disabled until power returns. Spa settings are preserved on all systems. Temperature is unknown. After the pump has been running for 2 minutes, the temperature will be displayed. "Overheat" - The spa has shut down. One of the sensors has detected 118˚F/48˚C at the heater.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 50 DOWN EAST (3 -4 PUMP SYSTEMS) Diagnostic Messages (cont.) Action Required Message Meaning Possible inadequate water, poor flow, or air bubbles are detected in the heater. Spa is shut down for 15 minutes. Check water level in spa. Refill if necessary. If the water level is okay, make sure the pumps have been primed. Press any button to reset, or this message will automatically reset within 15 minutes.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 51 FREEDOM SPA- SPECIFICATIONS Spa Model Spa Dimensions Electrical Required 670L 84"x72"x34" 240 volt 50 amp 300 gallons 490lbs/2950lbs 1 pump 24 Brunswick 83"x83"x36" 240 volt 50 amp 320 gallons 580lbs/3660lbs 1 pump 30 Brunswick 2 83"x83"x36" 240 volt 50 amp 370 gallons 600lbs/3680lbs 2 pumps 30 America’s Leader In Luxury Water Capacity 50 Weight Dry/Full Therapy Pumps M A S T E R Jet Count S PA S
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 52 DOWN EAST AND FREEDOM - 1 AND 2 PUMP SYSTEMS Initial Start-up When your spa is first actuated, it will go into Priming mode, indicated by “Pr.” The Priming mode will last for less than 5 minutes (press “Temp” to skip Priming Mode) and then the spa will begin to heat the spa and maintain the water temperature in the Standard mode. Warm/Cool (80˚F - 104˚F / 26˚C - 40˚C) The start-up temperature is set at 100˚F/37˚C.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 53 DOWN EAST AND FREEDOM - 1 AND 2 PUMP SYSTEMS Mode Mode is changed by pressing the “Warm” or “Cool” button, then pressing the “Light” button. Standard mode is programmed to maintain the desired temperature. Note that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes. “St” will be displayed momentarily when you switch into Standard mode.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 54 DOWN EAST AND FREEDOM - 1 AND 2 PUMP SYSTEMS Diagnostic Messages Action Required Message Meaning No message on display. Power has been cut off to the spa. The control panel will be disabled until power returns. Time of day will be preserved for 30 days on your system. Spa settings are preserved on all systems. Temperature is unknown. After the pump has been running for 2 minutes, the temperature will be displayed.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 55 DOWN EAST AND FREEDOM - 1 AND 2 PUMP SYSTEMS Diagnostic Messages (cont.) Action Required Message Meaning Possible inadequate water, poor flow, or air bubbles are detected in the heater. Spa is shut down for 15 minutes. Check water level in spa. Refill if necessary. If the water level is okay, make sure the pumps have been primed. Press any button to reset, or this message will automatically reset within 15 minutes.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 56 MAX STEREO SYSTEM / SPA THEATER SYSTEM (STS) Available on select Master Spa and Down East Models WARNING: Never remain in your spa longer than 15 minutes per session when the water temperature is above 98˚ F. If you wish to spend more time in your spa, whether enjoying music, watching tv, or just lounging, be sure to keep the spa water at or below body temperature (98.6˚ F).
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 57 MAX STEREO SYSTEM / SPA THEATER SYSTEM (STS) Available on select Master Spa and Down East Models Note: Speakers should be in the down position before covering your spa. Failure to do so will result in damage not covered under the warranty. Note: UV rays may interfere with the operation of the remote. Note: Do not place wet CD’s into the stereo at anytime. Note: Do not place wet DVD’s into the DVD player at anytime.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 58 MAX STEREO SYSTEM / SPA THEATER SYSTEM (STS) LS 750 STS, LS 800 STS, LS2X STS and LSX 1050 STS Note: We have included the stereo and DVD owner’s manual with your spa. This should be read to see the specific operation of these components. Note: Do not place wet DVD’s or CD’s into the players at any time. Resulting damage will not be covered under warranty.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 59 SPA THEATER SYSTEM (STS) / STEREO SYSTEMS (continued) LS 750 STS, LS 825, LS2X STS and LSX 1050 STS Your STS spa (and any spa with a stereo) comes equipped with a locking, water resistant enclosure for the DVD player and stereo. Figure 2 Figure 3 Figure 1 We have installed an F-81 television coaxial cable connector located under the front panel for your convenience.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 60 DOLPHIN REMOTE / KENWOOD A/V SYSTEM Legend Series All STS spas come with a Dolphin Remote Control.This remote uses both radio frequency and infrared signal to control TV, DVD, and Stereo functions. It will also operate the therapy pumps, spa light and fiber optics if so equipped. The blower and opt. 2 buttons are not used. The Dolphin Remote has 2 AA replaceable batteries.These may be replaced by removing the 5 screws on the back of the Dolphin.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 61 DOLPHIN REMOTE OPERATION Power Key: (A) Turns the power on and off to the TV and DVD. NOTE: To turn on the Kenwood CD player, use the Mode (F) button in the CD mode.To turn off the Kenwood stereo press and hold this button. Volume Buttons: (C) Adjusts the volume in the selected device. Channel Buttons: (H) In the CD mode, these buttons will scan CD tracks or scan radio presets. In TV mode, it will search through the TV channels.
07 Master/DE/Freedom Owners Manual 5/3/07 2:31 PM Page 62 DOLPHIN REMOTE OPERATION Setup Button: (J) Use this button to program device codes (see page 62).Your Dolphin Remote has been preprogrammed at the factory for all components included.When the batteries are replaced, the code for each component may need to be reprogrammed. Device Mode Buttons: (I) Select unit to control by pressing device button once.
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 63 DOLPHIN REMOTE Programming Device Codes: NOTE: Your remote has been preprogrammed at the factory for all components.When the batteries are replaced, these components may need to be reprogrammed. 1.) Select Device (I) The LED will blink once to confirm. 2.) Press and Hold the "Setup" button (J) The LED will blink once, and then twice to continue. 3.
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 64 DOLPHIN REMOTE SYSTEM OPERATION To Watch TV Turn on TV 1) Select Device (TV). (I) 2) Press Power. (A) 3) Select Tuner input using the Mode button. (F) Note:You may need to step through several unused video inputs. 4) Select desired channel. (E or H) Select input on CD player 1) Press power to select proper input. NOTE: The following procedure is for initial set up and programming of TV channels.
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 65 DOLPHIN REMOTE SYSTEM OPERATION To Watch DVDs Turn on TV 1) Select Device (TV). (I) 2) Press Power. (A) 3) Press Mode to select Video Input. (F) Turn on Stereo Stereo is always on unless Master Power button is pressed on the stereo. Turn on DVD Player 1) Select Device (DVD). (I) 2) Press Power. (A) 3) Load disc into DVD Player. 4) Press Play Button.
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 66 DOLPHIN REMOTE DEVICE MODES / FEATURE BUTTONS CD Mode (F) Mode This button will switch tuner to AM. (G) Enter This button will switch tuner to FM. (C) Vol Up / Down The main volume for the theater system is controlled through the stereo. (H) CH Up / Down These buttons will scan radio station presets and CD audio tracks. (A) Power Switches inputs. NOTE: AM stations will be very limited in reception and in most cases will be unavailable.
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 67 DOLPHIN REMOTE DEVICE MODES / FEATURE BUTTONS DVD Mode (C) Vol Up / Down Main audio is controlled through the CD stereo.These buttons will adjust DVD audio output level to the CD player. (A) Power This button will control power to the unit. (B) Directional Buttons These buttons will navigate through selections on the DVD menu. TV Mode (F) Mode This button selects the video or tuner input on the TV. (A) Power This button controls power to unit.
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 68 SPA TROUBLE SHOOTING GUIDE NOTHING ON THE SPA OPERATES1.) Check the control panel display for any messages. If there is a message, refer to the diagnostic section on that model spa.There you will find the meaning of the message and what action is to be taken. 2.) If there is no message on your control panel, check and reset the GFCI and house breaker. *The GFCI should be located in a weather proof box close to the spa, but no closer than 5 ft.
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 69 SPA TROUBLE SHOOTING GUIDE SPA NOT HEATING * If the spas heater has failed, the majority of the time it will trip the GFCI breaker. If the spa is not heating and has not tripped the breaker, please follow these steps: 1.) Check the control panel for diagnostic messages. Refer to your spa models diagnostic message area in previous sections. Follow steps to alleviate message. 2.) Check water set temperature at control panel. 3.
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 70 REGULAR MAINTENANCE PROCEDURES Note: These are areas that will require the spa owner to perform routine maintenance.These are not areas covered under the warranty of the spa. CLEANING JETS The majority of jets in your spa can individually be turned on/off. If any of these jets become hard to turn, it will be necessary to remove the jet to clean it as grit/sand and mineral deposit may be present.
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 71 REGULAR MAINTENANCE PROCEDURES CLEANING DIVERTER VALVES - cont. Turn the cap piece counter clockwise. It may be necessary to put a clean rag over the cap and turn it with a wrench. Once loose, the cap and handle can be pulled up out of the white plumbing fitting. Wipe down the internal piece that attaches to the cap and handle. Soak the cap and handle in white vinegar. The white plumbing fitting should also be wiped down.
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 72 REGULAR MAINTENANCE PROCEDURES REPLACING YOUR LIGHT BULB If your light bulb goes out, it is very easy to replace. Use a 12 volt, 6 watt bulb that should be available through your dealer. First, make sure the power to the spa is off.You can access the spa light fitting by removing the spa panel. Once the panel is removed, unfasten the black fitting inside the white light assembly, by turning it counter clockwise.
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 73 REGULAR MAINTENANCE PROCEDURES CARE OF YOUR SPA COVER Always cover your spa when not in use.This will greatly reduce energy consumption and will cause spa water to heat more rapidly.Water loss and chemical usage will also be reduced. • Be sure to lock down all straps on cover after each use to prevent wind damage. • Do not allow spa to sit uncovered in direct sunlight.
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 74 SPA CARE AND MAINTENANCE RECORD DATE DATE DATE DATE DATE DATE DATE DATE Drain & Clean Spa Clean Filter Cartridges Change ECO PUR™ Element Every 180 Days Soak Filter Cartridges in Solution Test GFCI Clean and Condition Spa Cover and Cabinet Miscellaneous Service America’s Leader In Luxury 73 M A S T E R S PA S
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 75 SPA CARE AND MAINTENANCE RECORD DATE DATE DATE DATE DATE DATE America’s Leader In Luxury DATE 74 DATE DATE DATE DATE DATE M A S T E R DATE S PA S
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 76 SPA CARE AND MAINTENANCE RECORD DATE DATE DATE DATE DATE DATE America’s Leader In Luxury DATE 75 DATE DATE DATE DATE DATE M A S T E R DATE S PA S
07 Master/DE/Freedom Owners Manual 5/3/07 2:32 PM Page 77 SPA CARE AND MAINTENANCE RECORD DATE DATE DATE DATE DATE DATE America’s Leader In Luxury DATE 76 DATE DATE DATE DATE DATE M A S T E R DATE S PA S
07 Master/DE/Freedom Owners Manual pop07ownman rev. 1/07 5/3/07 2:32 PM 6927 Lincoln Parkway Fort Wayne, Indiana 46804 1-800-860-7727 www.masterspas.