Light
Press the “Light” button to turn the light on and off. If left on,the light
automatically turns off after 4 hours.
L.E.D. Light
Press the "Light" button to turn the light on and off. If you wish to change the
"function" of the lights,turn the lights off,then on within 5 seconds. If you wish
to leave the lights in the same "function" setting for the next use,turn the lights
off and do not turn back on for at least 5 seconds.
Circ Pump
Your system may be configured to work in one of three different ways:
1.) The circ pump operates continuously (24 hours) with the exception of
turning off for 30 minutes at a time when the water temperature reaches
3˚ F (1.5˚C) above the set temperature (most likely to happen in very
hot climates).
2.) The circ pump stays on continuously, regardless of water temperature.
3.) The circ pump will come on when the system is checking temperature
(polling),during filter cycles, during freeze conditions,or when another
pump is on.
Preset Filter Cycles
On your MS5000 system,the circ pump,low speed of pump 1,and the ozone
generator will run during filtration.At the start of each filter cycle,the lowest
speed of all pumps will run for 5 minutes.
(The following is specific to all systems that are programmed according to time)
There are two filter cycles per day.The start/end times of each cycle are
programmable.To program,set time as instructed above,then press
“Program/Mode” to advance to the next setting (or to exit after the last setting).
The default filter cycles are as follows:
The first filter cycle is automatically activated at 8:00 AM and operates the pump
until 10:00 AM.The filter 1 indicator icon will light when filter 1 is running.
The second filter cycle is automatically activated at 8:00 PM and operates the
pump until 10:00 PM.The filter 2 indicator icon will light when filter 2 is
running.