Initial Start-up
When your spa is first actuated,it will go into Priming mode,indicated by “Pr.”
The Priming mode will last for less than 5 minutes (press “Warm”or “Cool”to
skip Priming Mode) and then the spa will begin to heat the spa and maintain the
water temperature in the Standard mode.
This system is equipped with a 24-hour circ pump.The circ pump and ozone
generator (if installed) run continuously.
Warm/Cool (80˚F - 104˚F / 26˚C - 40˚C)
The start-up temperature is set at 100˚F/37˚C.The last measured temperature is
constantly displayed on the LCD.
Note that the last measured spa temperature displayed is current only
when the pump has been running for at least 2 minutes.
To display the set temperature,press the “Warm”or “Cool”pad once.
To change the set temperature,press the pad a second time before the LCD stops
flashing. Each press of the “Warm”or “Cool” pad will continue to either raise or
lower the set temperature.
After three seconds,the LCD will stop flashing and display the current spa
temperature.
Jets 1
Touch the “Jets 1”button once to activate pump 1. Press the “Jets 1”button again
to turn off the pump. If left running,the pump will automatically turn off after
15 minutes.
Jets 2
Touch the “Jets 2”button once to activate the pump. Press the “Jets 2”button
again to turn off the pump.If left running,the pump will automatically turn off
after 15 minutes.