Instructions / Assembly

30
10
12
11
4
2
2120
3
5
1
E
EA
x1x1
A
18
ASSEMBLY, ASSEMBLAGE, ENSAMBLAJE
19
7
REGULATOR, BURNER AND GAS VALVE CONNECTION & OPERATION
IGNITION INSTRUCTIONS
CLOCKWISECLOCKWISE
COUNTER
CLOCKWISE
17.75”
(45cm)
APPROX.
12.25” (45cm)
APPROX.
Fig. 3
Fig. 1
MATCH LIGHT INSTRUCTIONS
1. Read all instructions and warnings before lighting.
2. Check control knob and gas cylinder valve to be certain it is in OFF position before connecting to
gas cylinder.
3. Perform soapy water test before each use.
4. Open door(s) during lighting and/or remove all accessories and cooking vessels from in/or on unit.
5. Turn gas cylinder valve ON, push control knob in, hold and and turn counter-clockwise to desired
temperature setting, after ignition continue holding control knob in for 5 seconds to activate the
ame sensor.
6. Place a long, lit fi replace match stick close enough to burner to ignite.
7. If ignition does not take place within fi ve seconds, turn control knob to OFF position and wait fi ve
minutes and repeat match light instructions.
8. After each use, fi rst turn control knob off , then gas cylinder valve off . Always allow unit to cool
completely before touching, moving or storing.
Inspect hose before each use. If there are signs of abrasion, wear, cuts, or leaks, the hose must be
replaced. DO NOT USE.
Inspect burner before each use. Check burner and burner venturi tube for insects and insect nests.
A clogged tube can lead to a fi re beneath unit.
Check to ensure the orifi ce is centered inside the venturi tube. Failure to properly assemble the
valve orifi ce to the venture tube can result in gas leak or potential fi re at connection. See assembly
steps for proper assembly method.
Check to ensure the igniter pin is properly spaced and aligned to the burner. Igniter pin should be
approximately 1/4” from the burner and aligned to the top of a burner port (Fig. 2). Confi rm spacing
is correct by pressing the igniter button and ensuring spark occurs between igniter pin and burner.
Connect hose regulator to LP Gas Cylinder
1. Make sure gas cylinder valve is closed. Turn valve clockwise until it stops.
2. Make sure control knob on smoker is in the OFF position.
3. Remove protective cap from gas cylinder and coupling nut if applicable.
4. Center and insert regulator nipple into valve outlet on gas cylinder (Fig. 1). Turn regulator
coupling nut clockwise until it stops. DO NOT OVER TIGHTEN.
Perform Soapy Water Test.
Before starting lighting procedure make sure the smoker door(s) are open.
When lighting burner remove all parts inside or on unit to prevent explosion from gas build up.
To use, turn gas cylinder valve ON, push control knob in, hold and and turn counter-clockwise to
desired temperature setting. Push ignitor button to light, after ignition continue holding control knob
in for 5 seconds to activate the fl ame sensor.
If ignition does not take place within fi ve seconds, turn control knob to OFF position and wait fi ve
minutes and repeat lighting procedures. If ignition still does not occur, see match light instructions.
Always ensure that smoker door(s) are open before igniting. Gas can accumulate in smoker.
If fl ame goes out during cooking, turn control knob OFF, turn gas cylinder valve OFF, wait 5
minutes, then open door(s) and wait 5 additional minutes before repeating ignition instructions
above.
Control knob sets the smoker to a desired temperature. Push control knob in and turn clockwise to
shut fl ame off .
Visually check burner fl ame (Fig. 3). A CORRECT FLAME should be blue with a small amount of
yellow at the tip. An INCORRECT FLAME is excessively yellow and irregular. If an incorrect fl ame
occurs, turn control knob to OFF position, turn OFF gas cylinder valve, allow unit to cool and then
clean burner. Let burner completely dry before re-lighting.
After use turn control knob OFF, then turn gas cylinder valve OFF and disconnect tank.
Type 1 Regulators will have a hook (Fig. 4). The Regulator Hook is used to keep the regulator off
the ground when removed from the LP cylinder. Attach to unit as shown in image.
Fig.4
1/4"
Fig. 2