Datasheet

Configuration Registers
3-28 Intel
®
E8870 Scalable Node Controller (SNC) Datasheet
3.8.8 SPC: Scalability Port Control Register
This register controls the SP cluster.
44:40 RO 11111
SP1 Node ID [4:0]
Device # received from SP1s idle flits.
39:32 RO FFh
SP1 Bus [7:0]
Bus # received from SP1s idle flits.
31:16 RV 0 Reserved
15 RWS 0
StopOnErr
0 - An agent will send idle or info flits when in
RETRY_LOCAL_IDLE state.
1 - If an agent has detected an error and has sent an LLRReq
and its local retry state machine is in RETRY_LOCAL_IDLE
state, then it should not send any info or idle flits and sends a Ctrl
flit with LLRIdle.
14 RWS 0
SndMultAck
0 - 0 or 1 ACK is sent in LCC[7] of idle flits. Byte D = 0.
1 - LCC[7] = 0. Up to 25 ACKs will be sent in Byte D[4:0] of idle
flits. Idle flits are forced whenever there are multiple acks to
send.
13 RWS 0
RcvMultAck
0 - 0 or 1 ACK is extracted from LCC[7] of idle flits.
1 - Up to 25 ACKs may be extracted from idle flits. Ack[4:0] =
LCC[7] || Byte D[4:0]. Any particular idle flit will use either LCC[7]
or Byte D, but not both.
12:8 RO 11111
SP0 Node ID [4:0]
Device number received from SP0s idle flits.
7:0 RO FFh
SP0 Bus [7:0]
Bus number received from SP0s idle flits.
Device: NodeID
Function: 2
Offset: 74h(31:0), 78h(63:32),7Ch(71:64) (Continued)
Bit Attr Default Description
Device: NodeID
Function: 2
Offset: 70h
Bit Attr Default Description
31:1 RV 0 Reserved
0RW1
SPBS: Single Processor Bus System
This bit should be set when the SNC is directly connected to an SIOH. The
SNC must order coherency operations according to the processor bus order,