TCDS Series Digital Clocks User Manual
TCDS Series User Manual – Rev. 2.0.2 Page 2 Table of Contents Forward ......................................................................................................................................... 5 Disclaimer..............................................................................................................................................................................5 Copyrights .......................................................................................................
TCDS Series User Manual – Rev. 2.0.2 Page 3 Specifications ............................................................................................................................... 27 Communications I/O ........................................................................................................................................................... 27 Power Requirements ...........................................................................................................................
TCDS Series User Manual – Rev. 2.0.1 Page 4 This page intentionally left blank.
TCDS Series User Manual – Rev. 2.0.1 Page 5 Forward Disclaimer The material in this document is for information only and subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, Masterclock, Inc. assumes no liability resulting from errors or omissions in this document or from the use of the information contained herein. Masterclock, Inc.
TCDS Series User Manual – Rev. 2.0.
TCDS Series User Manual – Rev. 2.0.1 Page 7 WEEE Waste Electrical and Electronic Equipment Directive (WEEE) 2002/95/EC The TCDS series is considered WEEE Category 9 (Monitoring and Control Instruments Equipment) as defined by the WEEE Directive and therefore fall within the scope of the WEEE Directive. For more information about Masterclock’s WEEE compliance and recycle program, please visit: http://www.masterclock.com/rohs_compliance.
TCDS Series User Manual – Rev. 2.0.1 Page 8 Introduction The TCDS is a precision, multi-featured time code driven digital time display. The TCDS decodes IRIG-B and SMPTE linear/longitudinal time code formats to function as a clock. IRIG-B Defined by the Range Commanders Council, U.S. Army White Sands Missile Range. The format is used by military, government, power industry and many other commercial and industrial applications.
TCDS Series User Manual – Rev. 2.0.1 Page 9 General Use Precautions Do not expose this clock to temperatures outside the range of 0° C to 50° C (32° F to 122° F). Placing your device in an environment that is too cold or humid may damage the unit. Do not place heavy objects on top of this clock or use excessive force on it. Never use benzene, paint thinners, detergent or other chemical products to clean the outside of this clock. Such products will disfigure and discolor the casing.
TCDS Series User Manual – Rev. 2.0.1 Page 10 Unpacking and Installation Supplied (Ship Kit) The list below is for illustration purposes. Refer to your sales order for actual items shipped.
TCDS Series User Manual – Rev. 2.0.1 Page 11 Connections Un-balanced Signal: Connect the 50 ohm (Ω) RG59 coaxial cable (not included) to the BNC connector, located on the back panel. Balanced Signal: Secure the wires (not included) to the terminal block, located on the back panel. AC: Insert the IEC, AC power cord into the IEC socket located on the back panel. UDC-RCU control: Insert the 6P6C cable, included with UDC-RCU, in to the RJ12 socket.
TCDS Series User Manual – Rev. 2.0.1 Page 12 Mounting The TCDS digital time display is designed for table, wall or rack mount. Power and low voltage signal wiring should be installed according to local electrical codes, so to access the back of the clock. Do not route power or signal cables between the case and the wall (along the exterior of the wall), which may pinch the power or signal cable and create a hazardous condition.
TCDS Series User Manual – Rev. 2.0.
TCDS Series User Manual – Rev. 2.0.1 Page 14 Rack Mount Bracket Attach the time code cable and power cord, and then secure the clock to the equipment rack or cabinet. Swivel Mount Bracket Mount both swivel brackets to the wall, attach the time code cable and power cord and secure the clock to the brackets using the supplied retaining screws.
TCDS Series User Manual – Rev. 2.0.1 Page 15 This page intentionally left blank.
TCDS Series User Manual – Rev. 2.0.1 Page 16 Operating Environment The TCDS contains microprocessor control electronics designed to operate indoors between 32˚ to 140°F (0˚ to 60˚C) with 0-90% relative humidity, non-condensing. The TCDS is not water or moisture proof. Treat it as you would any other delicate electronic device and do not expose it to water, excessive heat or physical abuse. Operation After applying power, the clock will go through an internal check.
TCDS Series User Manual – Rev. 2.0.1 Page 17 Time Zone Offsets The TCDS time display maintains time as UTC initially. A time zone offset or bias can be provided to adjust the time for display purposes. A bias can be set as a positive (+) or negative (-) value with a resolution of one second. If the time code being input into the TCDS is different from UTC do not adjust the time zone and/or DST offset.
TCDS Series User Manual – Rev. 2.0.1 Page 18 Freewheeling Accuracy The TCDS has built-in provisions to allow the clock to freewheel and maintain accuracy for extended periods in the absence of time code. These features also allow the unit to be set manually and run without time code with precision.
TCDS Series User Manual – Rev. 2.0.1 Page 19 This page intentionally left blank.
TCDS Series User Manual – Rev. 2.0.1 Page 20 TCD-Set The TCD-Set configuration utility is a program designed to run under the Microsoft Windows operating system and is supplied with the time code clock. Installation To install the software program on your Windows server, workstation or PC, complete the following steps. 1. Insert the CD, “Time Code Products”, supplied with your time display. 2. Run “Setup_TCD-Set.exe” executable file from the TCDS folder.
TCDS Series User Manual – Rev. 2.0.1 Page 21 USB Device Driver A USB type B port has been included on the rear cover of the clock to provide a means of configuring the clock via software and to allow for firmware upgrades for either firmware corrections or future product enhancements. To utilize the USB port, connect a USB type A to USB type B cable from the computer to the clock.
TCDS Series User Manual – Rev. 2.0.1 Page 22 Using TCD-Set, USB Configuration Utility Open TCD-Set from the “Start Menu” or by double-clicking the shortcut icon on the desktop. The lower left section of the main window shows the model, firmware version and serial number of the clock. Above that is the current status of the clock display. This information is continually updated. Local Time is the time displayed on the clock, including any time zone and/or DST offset information.
TCDS Series User Manual – Rev. 2.0.1 Page 23 This is a screenshot of TCD-Set when connected to a TCDS112, which has two 6-digit display sections, so it can display a second time with its own time zone and DST settings: Click [Apply] from the main window to save the modified settings made from the sub-menus (i.e. Time Zone, Daylight Savings Time, Time Code Settings, etc.). The “Local Time” field is displayed in the 24 hour format, even if the clock’s display is set to the 12 hour format.
TCDS Series User Manual – Rev. 2.0.1 Page 24 Time Zone Offset Modify the time zone by clicking the [Time Zone] button. This opens a new window that gives you a list of time zones, including descriptions to help with the selection. Select the desired time zone and click [OK] to close the window. Changes are applied when you click [OK]. Daylight Saving Time Configure and/or enable the daylight saving function by clicking the [Daylight Saving Time] button.
TCDS Series User Manual – Rev. 2.0.1 Page 25 Time Code Settings To use the automatic DST adjustments requires that date/year encoding is enabled. This product contains an automatic detection and gain control circuit for the incoming SMPTE 30/25/24 fps longitudinal/linear time code or for IRIG-B(0) pulse width modulated or IRIG-B(1) amplitude modulated time code.
TCDS Series User Manual – Rev. 2.0.1 Page 26 Set Date Time The [Set Date Time] feature lets you manually set the time and date for the clock. This may be most useful for lab situations as the clock keeps time via its internal precision oscillator and realtime clock when time code is not present. The time can either be set to the time of the Windows PC or a manual time and date can be entered. Practical use of this feature requires the clock to be removed from the time code source.
TCDS Series User Manual – Rev. 2.0.1 Page 27 Specifications Communications I/O USB……………………........................................B type connect Format……………………………………………………..v1.1 Time Code Formats I N P U T S SMPTE – 30 fps SMPTE – 25 fps (EBU) SMPTE – 24 fps (FILM) IRIG-B* pulse width modulated IRIG-B(1)* amplitude modulated DST supported Masterclock/Leitch IEEE - 1344 Date Encoding Year Encoding √ √ √ √ √ Type…………………………………… .........................
TCDS Series User Manual – Rev. 2.0.1 Page 28 Power Requirements AC AC Input Voltage ..................................... 90-265 VAC AC Input Frequency ................................. 47-63 Hz AC Input Connector ................................. Universal IEC input connector AC power consumption ........................... 10 W There are no user serviceable parts inside the TCDS digital clock. Please contact Masterclock, Inc. if you require servicing or repair.
TCDS Series User Manual – Rev. 2.0.1 Page 29 Care and Cleaning Adherence to regular and proper cleaning procedures is recommended to preserve appearance. Scratched or otherwise damaged lens caused by misuse, mishandling and improper storage or improper cleaning is not covered under the limited warranty. Job Site Precautions It is recommended the clock be removed from the wall and stored face up in its protective shipment bag during painting and construction.
TCDS Series User Manual – Rev. 2.0.1 Page 30 Minimize Hairline Scratches Always store the clock face-up in the protective plastic shipping bag until ready for installation and during transporting to the installation site. Do not place the clock face (lens surface) down on any surface as this may scratch or mar the lens. Scratches and minor abrasions can be minimized by using a mild automobile polish.
TCDS Series User Manual – Rev. 2.0.1 Page 31 Troubleshooting The easiest way to verify that TCDS is decoding time code is to observe the LED colons on the front of the clock. The colons will be on continuously when the TCDS synchronized to a time source (i.e. decoding time code). If the colons are flashing at a rate of 1 pulse per second or dashes are displayed, then there is an issue with the input time code signal.
TCDS Series User Manual – Rev. 2.0.1 Page 32 Not displaying the correct local time and/or date. Possible reasons/solutions: 1. The TCDS has a time zone offset and/or DST offset configured. 2. Your time code source and/or the TCDS are set with time zone and/or DST offsets. 3. Your time code source is not providing the time and/or date that you expect. Contact the individual responsible for the time code source for more information. Clock did not properly negotiate the DST. Possible reasons/solutions: 1.
TCDS Series User Manual – Rev. 2.0.1 Page 33 Limited Warranty This Masterclock, Inc. product warranty extends to the original purchaser. Masterclock warrants this product against defects in materials and workmanship for a period of one year from date of sale. If Masterclock receives notice of such defects during the warranty period, Masterclock will, at its option, either repair or replace products that prove to be defective.
TCDS Series User Manual – Rev. 2.0.1 Page 34 Service Information We sincerely hope that you never experience a problem with any Masterclock product. If you do need service, contact Masterclock’s Technical Support team. A trained specialist will help you to quickly determine the source of the problem. Many problems are easily resolved with a single phone call or email. If it is necessary to return a unit to us, an RMA (Return Material Authorization) number will be given to you.
Masterclock, Inc. 2484 West Clay St. St. Charles, MO 63301 +1-(636)-724-3666 1-800-724-1778 support@masterclock.com sales@masterclock.