User Manual

INSTRUCTIONS:
1. Read the vacuum pump instructions. After making sure that all
refrigerant has been recovered from the system, connect your
vacuum pump. Make sure that the oil drain on the bottom of the
pump is closed and that your pump is filled with the sufficient
amount of oil.
2. The red and blue hoses are to be connected from the manifold
red and blue valves to the system’s high and low pressure ports.
Charging Station Instructions
The charging station consists
of a frame with roller wheels
and three main components:
• Vacuum pump:
See separate
service manual
• Charging scale:
See separate
service manual
• Manifold:
a. 4 way equipped with
four ball valves
b. Standard piston style
2 valve manifold
Note: make sure that the exhaust is taken
off the pump prior to starting.
Failure to do so may cause internal
damage or pump housing to crack.
OPERATION:
1. Evacuation:
After making sure all hoses are connected properly, open
red and blue valves on the manifold. Begin to evacuate
your system by turning on your vacuum pump. After
sufficient vacuum has been reached, you can turn off your
pump and disconnect.
2. Charging System:
Depending on 2 way or 4 way manifold use, now check
and make sure that you have your service (yellow) hose
connected to your refrigerant tank. Turn on your scale from
the monitor and then place your tank on the platform after
the scale has finished its countdown. At this point open
your blue and red valves on the manifold and then open
the valve on your refrigerant tank. The charging process
will begin at this point and the amount being charged to
your system and be viewed on the scale monitor.
Depending on outside temp.conditions, you may need the
assistance of a heater blanket around your tank to speed
up the charging process. Once your desired charge
amount is reached, close all valve and then disconnect
all hoses, as you charge process is complete.
3. Take the charging scale out of its location at the back of the
station’s frame. Read the instructions. Take the platform and
monitor out of their black plastic carrying case. Make sure
that the platform is put on a stable and even surface. Do not
leave the platform in the box. The monitor can then be placed
in the bracket on the top right hand corner of the frame.