Installation Instructions

Page 11
OPERATION
CHARGING A HOT
BATTERY PACK
If the battery pack is above the normal
temperature range, the red LED will illuminate
and the green LED will be off. When the
battery pack cools down to approximately
122°F (104°F for Ni-Cd battery), the charger
will automatically begin charging.
CHARGING A COLD
BATTERY PACK
If the battery pack is below the normal
temperature range, the red LED will
illuminate and the green LED will be off.
When the battery warms to a temperature
of more than 41°F (5°C), the charger will
automatically begin charging .
DEFECTIVE BATTERY
If the charger detects a problem, the red LED
will begin ashing and the green LED will be off.
1. If registering as defective, remove and
reinsert the battery pack in the charger.
If the LED status reads “defective” a
second time, try to charge a different
battery pack.
2. If a different battery pack charges
normally, dispose of the defective
battery pack (see Maintenance section).
3. If a different battery pack also indicates
“defective,” the charger may be defective.
BATTERY CHARGING
If the battery pack is within the normal
temperature range, the green LED will begin
ashing and the red LED will be off, the four
green LEDs on the battery pack will ash
one by one from right to left.
BATTERY FULL
After the battery is fully charged, the green
LED Light on the charger will be on and the
red LED light will be off; the green LEDs on
the battery will shine for approximately 30
minutes and then turn off.
NOTICE: The battery pack will fully charge,
but will not overcharge, if left on the charger.
NOTICE: Charger may warm with several
continuous charge cycles. This is part of
the normal operation of the charge. Charge
in a well ventilated area.
WALL-MOUNT HOLES
The charger has hanging holes for
convenient storage. Install screws in the wall
3-1/4 inches apart. Use screws sufciently
strong to hold the combined weight of the
charger and battery pack.