User Manual

Table Of Contents
Edit Setup Mode
TheParametersofaSetup
8-2
The Parameters of a Setup
A Setup has 43 Zone-specific parameters for each of four Zones, and two common
parameters—altogether, there are 174 parameters whose configurations determine the
behavior of the Setup. As you scroll through the list of parameters using the Chan / Param
Up (
̂
) button, the parameters appear in the following order (the parameters of course
appear in the reverse order if you scroll through the list with Chan / Param Down (
̌
)
button):
List No.
Parameter Range of Values Default Value
Z. 1 Z. 2 Z. 3 Z. 4
1 44 87 130 LocalProgram ProgramList 0GrandPiano
2 45 88 131 Channel 1to16 1
3 46 89 132 Destination Local,MIDI,
Local+MIDI
Local+MIDI
4 47 90 133 MIDIBank 0to127 BankofLocal
Program
5 48 91 134 MIDIProgram 0to127 ProgramNumberof
LocalProgram
6 49 92 135 BankMode None,Ctl0,Ctl32,
Ctl0/32,K2600
Ctl0/32
7 50 93 136 ZoneStatus Active,Muted Active
8 51 94 137 EntryProgram
Change
Off,On On
9 52 95 138 AuxSendLevel 0to127 20
10 53 96 139 Transpose -128to127ST 0
11 54 97 140 EntryPan 0to127 64
12 55 98 141 EntryVolume 0to127 127
13 56 99 142 LowVelocity 1to127 1
14 57 100 143 HighVelocity 0to127 127
15 58 101 144 LowKey C-1toG9 (none)
16 59 102 145 HighKey C-1toG9 (none)
17 60 103 146 BendRangeDown 0to127ST 12ST
18 61 104 147 RendRangeUp 0to127ST 12ST
19 62 105 148 ModWheelDestina-
tion
MIDIDestinationList (none)
20 63 106 149 ModWheelEntry
Value
0to127 (none)
21 64 107 150 ModWheelExitValue 0to127 (none)
22 65 108 151 ControlKnobFunc-
tion1Destination
MIDIDestinationList (none)
23 66 109 152 ControlKnobFunc-
tion1EntryValue
0to127 (none)
24 67 110 153 ControlKnobFunc-
tion1ExitValue
0to127 (none)
25 68 111 154 ControlKnobFunc-
tion2Destination
MIDIDestinationList (none)
26 69 112 155 ControlKnobFunc-
tion2EntryValue
0to127 (none)
27 70 113 156 ControlKnobFunc-
tion2ExitValue
0to127 (none)
Zone 1
Parameters
Zone 2
Parameters
Zone 3
Parameters
Zone 4
Parameters
Common
Parameters
43 43 43 43 2