Installation Manual
ChargeMaster Plus 12/75-3, 12/100-3, 24/40-3, 24/60-3 – User and Installation Manual 
21 
4.2.5  Events – System automation 
A CZone/MasterBus device can be programmed to initiate an action at another connected device. This is 
very helpful in automation of your system but is not required. 
In MasterBus this is done by means of event-based commands. In the Events tab you can program the 
ChargeMaster  Plus  to  act  as  an  event  source.  Events  which  occur  during  the  operation  of  the 
ChargeMaster Plus will then trigger actions from other products. The following tables list the parameters 
as shown in MasterAdjust. 
Field 
Meaning 
Value 
Event x source 
Select an event that triggers an action, for example 
Battery pre low. 
See Event source list 
Event x target 
Select the device that should act, for example the 
generator 
Selectable targets are 
system dependent 
Event x command 
Select the parameter that must be changed on the 
target device, for example Activate. 
See command list of the 
selected device 
Event x data 
Data, for example On, is linked to the command. 
Off, On, Copy, Copy Invert, 
Toggle 
Table 1: MasterBus event parameters 
The ChargeMaster Plus can be configured as an event source. An event source can be used to initiate 
an event command and an event action by another device. 
Event source 
Meaning 
Charger state 
State of the ChargeMaster Plus serves as an event source 
Bulk 
Bulk state of charge serves as an event source 
Abs 
Absorption state of charge serves as an event source 
Float 
Float state of charge serves as an event source 
Failure 
Any fault condition of the ChargeMaster Plus serves as an event source 
Table 2: ChargeMaster Plus MasterBus Event sources 
When the ChargeMaster Plus is configured as an event target by another device, this device can initiate 
an event command and an event action to be performed by the ChargeMaster Plus. 
Event command 
Meaning 
On 
Command to switch on the ChargeMaster Plus 
Bulk 
Command to start the Bulk state of charge 
Abs 
Command to start the Absorption state of charge 
Float 
Command to start the Float state of charge 
Suspend charging 
When using a MLI Ultra Li-ion battery, this event is obligatory. Refer to the MLI 
Ultra manual. 
Table 3: ChargeMaster Plus MasterBus Event commands 