Malfunction
Possible cause
What to do
Batteries are discharged
too fast
Battery capacity reduced due
to wastage or sulphation,
stagnation
Charge and recharge a few times,
this might help.
Check battery and replace if
necessary
Batteries are too warm,
gassing
Defective battery (short circuit
in cell)
Check battery and replace if
necessary
Battery temperature too high
Use the battery temperature sensor
Charge voltage too high
Check settings (see chapter 4)
Remote panel display
shows no ChargeMaster
Plus
Display is switched off
Switch on display, refer to display
manual
Error in the wiring
Check the network cables
No terminating device placed at
the ends of the network
A network needs a terminating device
on both ends of the network, check if
available
Network is configured as a ring
network
Ring networks are not allowed. Check
the connections of the network.
ChargeMaster Plus is not
configured in CZone
configuration file
Open CZone Configuration Tool and
check.
ChargeMaster Plus Dipswitch
not correct
Open CZone Configuration Tool and
check with Force Dipswitch for
Address.
Slow or no MasterBus
communication.
Error in the MasterBus wiring
Check the network cables
No MasterBus Terminator
placed at the ends of the
network
MasterBus needs a terminating
device on both ends of the network.
Check if connected
MasterBus network is
configured as a ring network or
there are T-connections
Ring networks and T-connections are
not allowed. Check the connections
of the network