Use the following wire colors for DC wiring color 
or  at  least  different  colors  to  make  a  clear 
distinction  between  the  positive  and  negative 
wire from the battery: 
Wire color 
Meaning 
Connect to: 
Red 
Positive 
+ (POS) 
Black 
Negative 
– (NEG) 
Run  the  positive  and  negative  cables  next  to 
each  other  to  limit  the  electromagnetic  field 
around the cables. The negative cable should be 
connected  directly  to  the  negative  post  of  the 
battery  bank  or  the  ground  side  of  a  current 
shunt.  Do  not  use  the  chassis  frame  as  the 
negative  conductor.  Tighten  securely.  The 
positive  battery  cable  must  be  fused  and 
connected  to  the  positive  post  of  the  battery 
bank. 
The recommended DC fuses for DC 1 OUT, DC 
2 OUT and DC 3 in/OUT are: 
Model 
DC fuse 
Model 
DC fuse 
12/75-3 
85A 
24/40-3 
50A 
12/100-3 
125A 
24/60-3 
80A 
The  fuse  with the  fuse-holder  is  available  from 
your  local  Mastervolt  distributor  or  Customer 
Service Representative. 
3.3.2  AC wiring 
WARNING! 
On  first  connecting  to  power, 
make  sure  the  ChargeMaster 
Plus is in a well-ventilated area as 
it might spark. 
For  a  safe  installation  the  correct  wire  cross 
section  must  be  applied.  Don’t  use  a  cross 
section  that  is  smaller  than  indicated.  See  the 
following  table  to  select  the  appropriate  cross 
section for the AC wiring (up to 6m / 20ft length): 
AC Current 
Minimum cross section: 
in mm² 
AWG 
6-12A 
1.5mm² 
AWG14 
12-20A 
2.5mm² 
AWG12 
20-32A 
4.0mm² 
AWG10 
Connection of AC wiring and recommended wire 
colors: 
•  240VAC, 50/60Hz installations: 
Wire color 
Meaning 
Must be 
connected to:  
Brown or black 
Phase 
L1 
Blue 
Neutral 
N 
Green/Yellow 
Earth 
PE / GND 
•  120VAC, 50/60Hz installations (single phase): 
Wire 
color 
Meaning 
Must be 
connected to:  
Black 
Hot or Line 
L1 
White 
Neutral 
N 
Green 
Ground 
PE / GND 
•  240VAC, 50/60Hz (split phase 120/240VAC): 
Wire 
color 
Meaning 
Must be 
connected to:  
Black 
Hot or Line 
L1 
Red 
Hot or Line 
L2 
Green 
Ground 
PE / GND 
Note:  An  accessible  disconnection  device 
(switch  or  circuit  breaker  for  example) 
must be incorporated in the AC wiring, in 
accordance with wiring rules. 
3.3.3  AC safety grounding 
WARNING! 
The ground wire offers protection 
only  if  the  enclosure  of  the 
ChargeMaster  Plus  is  connected 
to the safety ground. Connect the 
ground terminal (PE / GND) to the 
hull or the chassis. 
CAUTION! 
According  to  local  regulations  an 
RCD/Breaker  (also  known  as 
GFCI)  must  be  placed  in  the  AC 
input  circuit  of  the  ChargeMaster 
Plus. 
For Australia and New Zealand, the 
wiring rules are in accordance with 
AS/NZS 3000. 
3.3.4  Network wiring (CZone/MasterBus) 
The ChargeMaster Plus can be connected to a 
CZone or MasterBus network. Use an RJ45 Drop 
cable CZone/MB or MasterBus cable and daisy 
chain  the  ChargeMaster  Plus  to  the  other 