Product Card

Specifications
Communication & monitoring
Communication interfaces MasterBus, CZone, NMEA
General specifications
Nominal output voltage 24 V
Max. output current primary output 40 A
Smart In-/Output output voltage 12 or 24 V
Smart In-/Output output current 5-10 A at 12 V; 5-20 A at 24 V (adjustable)
Smart In-/Output input current max. 20 A at 24 V
Total charge current 40 A at 28.8 V
Max. AC current (230 V / 120 V) 6.8 A / 13.5 A
Number of battery outlets 3 (max.)
Battery bank size 160-400 Ah
Nominal input voltage 120/230 V (80-275 V) 50/60 Hz
AC connection screw terminals, suitable up to up to 6 mm²
Power supply mode yes
Galvanic isolation yes
Display/read-out LED display
Dimensions, hxwxd 384 x 250 x 127 mm
15.1 x 9.8 x 5.0 inch
Weight 5.9 kg
13.0 lb
Compliance CE, ABYC, UL1236, SAE J1171, ISO 8846, CEC/DOE, RCM/C-Tick, RMRS,
RRR
Technical specifications
Charge characteristic IUoUo, automatic / 3-step+ for Gel/AGM/flooded/Lithium Ion + user
defined option
Temperature compensation -60 mV/°C / -76 mV/°F; temperature sensor included
DC voltage compensation through automatic compensation or MasterShunt
Power consumption (DC side) < 2 mA (MasterBus off)
Current Control function yes, through MasterBus or CZone
Power factor control > 0.98
Temperature range (ambient temp.) -25 °C to 80 °C, derating < 0 °C and > 40 °C
-13 to 176 °F
Cooling vario fan
Protection degree IP23, vertical mounting
Protections over-temperature, overload, short circuit, high/low battery voltage,
ignition protection
Charger Status Interface (alarm contact) yes, using a Multipurpose Contact Output (code 77030500)