8 Operation
Switching ON and Power Saving
Move the main switch to position I (ON) or II (POWER SAVING).
Power saving mode scans the output and compares the detected load to the threshold value (40W). If a
load is detected which is below the threshold value, the inverter switches to power saving mode. If a
load is detected higher than the threshold value, the inverter is switched on.
Switching OFF
Move the main switch to the position O (OFF). Note that switching off the AC Master does not
disconnect the batteries!
LED indicators
Output LED Sine Wave LED Power LED Meaning
Continuous (green) Continuous (green) Continuous (green) Inverter OK
Blinking (green) Blinking (green) Continuous (green) Power Saving
Off Continuous (red) Continuous (green) Inverter fault
Off Blinking slowly (red) Continuous (green) Battery voltage low/high
Off Blinking fast (red) Continuous (green) Short circuit
Off Off Off Inverter off