Product specifications

2120
475.5
315
254
282
294
10.5
10.5
21
405.5
34
QS6400 QS6400 Max-I
Generic article no. 130606400 130706400
see the Mastervolt price list for the specific country versions and article numbers
GENERAL
Typical string length 5 to 9 modules of 72 cells, 4 to 6 modules of 72 cells,
7 to 12 modules of 54 cells or 6 to 9 modules of 54 cells or
10 to 18 modules of 36 cells 8 to 12 modules of 36 cells
Operating temperature -20 °C to 50 °C, protected against high temperatures
Storage temperature -20 °C to 70 °C -20 °C to 70 °C
Relative humidity max. 95% not condensating; PCB has anti-moisture coating
Protection degree IP23 IP23
Safety class class I class I
Galvanic isolation class II class II
Dimensions (hxwxd) 476 x 315 x 254 mm 476 x 315 x 254 mm
Weight 14 kg 14 kg
SOLAR INPUT (DC)
Nominal power to 40 °C ambient temp. 5500 W or 4870 W DC* 5500 W or 4870 W DC*
PV power range 3200 to 7200 Wp 3200 to 7200 Wp
Maximum DC power 5900 W 5900 W
MPP Tracker (dynamic) 4 MPP trackers 4 MPP trackers
MPP voltage range 100 to 380 V DC 75 to 260 V DC
Maximum voltage 450 V DC 325 V DC
Nom. rated current 4x 7.5 A 4x 10 A
or 2x 15 A or 2x 20 A
Start-up power (power drawn from the solar side) 8 W 8 W
String connections 4x 2 4x 2
DC connector glands + PCB spring terminals 4 mm
2
max. or MultiContact connectors
GRID OUTPUT (AC)
Voltage 230 V (184 to 265 V, depending on the model), single or double phase
Nom. AC power 5200W or 4600 W* 5200 W or 4600 W*
Max. AC power 5500W or 4600 W* 5500 W or 4600 W*
Current (fused) 2x 12 A 2x 12 A
Frequency 50 Hz (48 to 52 Hz, depending on the model)
Power factor 0.99 0.99
THD <3% @ rated load; in compliance with IEEE p929
Stand-by power 0 W (DC voltage controlled relay)
European efficiency 94% 94.5%
Maximum efficiency 95% 96%
AC connector gland with PCB spring terminals
* Limited to 4600 W AC (4870 W DC) in case of ENS and one-phase feeding; two-phase feeding with 5200 W AC (5500 W DC) possible.
Sunmaster QS6400 IP23 product specifications
Mastervolt Guarantee Plan 5-year product warranty worldwide service 48-hour replacement service
SAFETY DEVICES
General galvanic separation between DC and AC side, by means of a class II HF transformer
Island protection ENS models: redundant impedance, voltage and frequency window monitoring;
independent switch off by two pole relay and solid state switch; VDE V 0126-1-1:2006 compliant.
QNS models: redundant voltage and frequency window monitoring;
independent switch off by two pole relay and solid state switch.
Temperature protection power derating at Ta
mbient
>40 °C; switch off at Ti
ndoor
>90 °C
DC side protection earth fault detection over-voltage detection
polarity protection (diodes) current limitation
transients (varistor and buffer capacitor) overload (temperature controlled power derating)
AC side protection current limitation over and undervoltage
over and underfrequency short circuit (ceramic fuse)
transients / surge (varistors)
Reclosure time 10 to 300 s (model dependent)
MONITORING
On the front six LEDs for indication of power and system diagnosis
External communication two RS485 connections to connect to the QS databus
Monitoring (optional) QS display: integrated LCD (standard for ENS models)
Data Control Basic: software for PC (shareware from www.mastervolt.com)
QS PC-Link: to connect the QS databus to the PC
Data Control Premium II: datalogger and software with telephone and modem dial-up facilities
Data Control Professional: datalogger using meteo data from the internet
Certificates
All Sunmaster solar inverters have been approved by local authorities, which is an indispensible guarantee for safe and reliable
functioning. The certificates in the Download & Support Area of our www.mastervolt.com website represent some of the documents
we have obtained, allowing trouble-free use in the United Kingdom, Germany, the Netherlands, Denmark, the Scandinavian countries,
Spain, France, Italy, Greece, Cyprus and Korea.
Dimensions QS6400 and QS6400 Max-I, in mm.