Product specifications
2928
Data Control Pro 230 V - GSM modem,
a
rt. no. 130396220.
Accessories Data Monitoring
DC Pro irradiance sensor 0 to 10 V,
temp. compensated, art. no. 130394410.
DC Pro irradiance and temperature sensor
0 to 10 V, art. no. 130394400.
Data Control Pro 230 V-ISDN
in enclosure, art. no. 130396310.
DC Pro ambient temperature sensor
0 to 10 V, art. no. 130394420.
Documentation CD Data Control Pro,
includes user manual, installation
information and drawings.
PT100 converter,
art. no. 130394440.
Model RS485/USB ISO,
art. no. 130391040.
PC-Link Industrial, for the connection of more than 10 Sunmasters or 25 mtr connection cable.
Model RS485/232 converter,
art. no. 130391020.
Data Control Basic
Data Control Premium II & Data Control Pro
PC-Link,
art. no. 130391010.
Online visualising of energy
production during one day
compared to the sun irradiation
based on current online
weather data by Safer’Sun.
A QS data port connects all the
inverters with the data logger.
The collected
data is sent to
the internet.
Data Control Pro.
Internet data monitoring : Data Control Pro
The Data Control Professional data logger provides monitoring,
read outs and alarm warnings via the internet. During the day,
the data logger extracts information on power output directly
from up to 20 Sunmaster inverters via the QS data port. This
eliminates the need for external kWh meters. Overnight, the
collected data is sent to a web page, from which it can later be
accessed from anywhere in the world using a log in code.
Exceptionally accurate weather prediction data is used to assess
the output of the PV system. An important advantage of the
system is the link from the local monitoring to the weather
registration of Meteomedia in Germany. An external reference
cell is not required.
Should the Sunmaster inverters report a system fault or the solar
yield not conform to the expected specified value, an alarm
routine of the Safer Sun Programme is activated. According to
the settings, an alarm is triggered on site at the device itself or a
warning message is sent by email, fax or SMS. This superior
monitoring method ensures a high availability of the recording
device, which in turn enables a large number of systems to be
monitored.
Data Control Pro specifications
Data logger Data Control Pro
Integrated modem analogue ISDN GSM
Art. no. 1303.96.2xx xx = 00 xx = 10 xx = 20
INTERFACES
Input analogue 4 (0 to 20 mA, 0 to 10 V)
Input digital 4 (meters / status)
Bus connection 1 (RS485)
Internet connection Ethernet
Alarm output 24 V DC / 230 V AC, 2
ELECTRICAL DATA
Grid connection 230 V AC
Power 2 W (max.)
MECHANICAL DATA
Dimensions (hxwxd) 90 x 160 x 73 mm
Mounting hat rail mounting
Protection degree IP20
ENVIRONMENTAL CONDITIONS
Operating temp. 0 °C to 55 °C
Storage temp. -20 °C to 65 °C
Data logger all current measured values and
system data of the inverters
MINIATURE WEB SERVER
Data recording and evaluation with Safer’Sun:
• Automatic daily data recording with high resolution
• Evaluation per day, month and year
• Graphic data display
• Alarm messages via fax, SMS, email
•
Automatic comparison with the actual, regional irradiance data
• Worldwide access through the Internet