Product specifications

3534
Mastervolt Guarantee Plan 2-year product warranty worldwide service pure sine wave power galvanic isolation
Overview sine wave inverters - AC Master range
AC Master AC Master AC Master AC Master
12/200 12/350 24/200 24/350
Article no. 230 V - continental European socket CEE-7/7 28010200 28010350 28020200 28020350
Article no. 230 V - IEC-1 socket 28010201 28010351 28020201 28020351
Article no. 120 V/60 Hz - US socket NEMA 5-15 n.a. 28510350 n.a. n.a.
GENERAL SPECIFICATIONS
Nominal battery voltage 12 V 12 V 24 V 24 V
Nom. power Tamb= 40 °C, cos phi 1 200 VA 350 VA 200 VA 350 VA
Peak load 400 VA 700 VA 400 VA 700 VA
Output waveform true sine true sine true sine true sine
Max. efficiency 90% 90% 93% 89%
Output voltage 230 V, ±5% 230 V, ±5%* 230 V, ±5% 230 V, ±5%
Frequency ------------------ 50 Hz, ±0.005% (60 Hz selectable)* ------------------- ------------------ 50 Hz, ±0.005% (60 Hz selectable)* -------------------
Dimensions (hxwxd) 74 x 152 x 242 mm 74 x 152 x 242 mm 74 x 152 x 242 mm 74 x 152 x 242 mm
Weight 1.65 kg 1.85 kg 1.65 kg 1.85 kg
Protection degree IP21 IP21 IP21 IP21
Min. battery capacity >50 Ah >80 Ah >25 Ah >40 Ah
TECHNICAL SPECIFICATIONS
Switch off voltage low battery 10.5 V, ±0.5 V 10.5 V, ±0.5 V 21 V, ±0.5 V 21 V, ±0.5 V
Switch on voltage low battery 11 V, ±0.5 V 11 V, ±0.5 V 22 V, ±0.5 V 22 V, ±0.5 V
Switch off voltage high battery 16 V, ±1 V 16 V, ±1 V 32 V, ±1 V 32 V, ±1 V
Switch on voltage high battery 15.5 V, ±1 V 15.5 V, ±1 V 31 V, ±1 V 31 V, ±1 V
Max. allowable riple on DC 5% RMS 5% RMS 5% RMS 5% RMS
Input current (nom. load) 23 A 38 A 15 A 25 A
No load power consumption :
Off mode 0 mA 0 mA 0 mA 0 mA
high power mode (230 V) 0.8 A / 9.6 W 0.8 A / 9.6 W 0.5 A / 12 W 0.5 A / 12 W
DC fuse required (slow blow) 30 A 40 A 20 A 30 A
Min. DC cable size supplied supplied supplied supplied
Harmonic distortion typical 3% 3% 3% 3%
Cooling ---------------------------- conventional / forced ---------------------------- ---------------------------- conventional / forced ----------------------------
Cos Phi -------------------------- all power factors allowed -------------------------- -------------------------- all power factors allowed --------------------------
Operating temperature specified -------------------- full spec 0 °C to 40 °C ambient temperature, 40 °C to 60 °C derating with 5% /°C. Shutdown @ 80 °C heat sink temperature. --------------
(will meet specified tolerances)
Practical operating temperature --------------------------- -25 °C to 40 °C ambient temperature, 40 °C to 60 °C derating with 5%/°C. Shutdown @ 80 °C heat sink temperature. ---------------
(may not meet specified tolerances)
Relative humidity --------------------- Max. 95%, non condensing; protected against humidity and condensing air by conformal coating on both sides of all PCB’s. -----------------
Standard and Approvals -------------------------------- CE, E-marking -------------------------------- -------------------------------- CE, E-marking --------------------------------
* 120 V model: 120 Volt, ±5% / 60 Hz, ±0.005%.