Product specifications

3736
Mass Sine Mass Sine Mass Sine Mass Sine Mass Sine Mass Sine Mass Sine Mass Sine Mass Sine Mass Sine Mass Sine
12/500* 12/800 12/1200 12/2000 24/800 24/1500 24/2500 24/5000 24/10kVA 24/15kVA 48/2500
Article no. 230 V 26010510 24010800 24011200 24012000 24020800 24021500 24022500 24095100 24026000 24027000 24042500
Article no. 120 V** 27010510 n.a. 25011000 25012000 n.a. 25021000 25022500 25024000 n.a. n.a. n.a.
GENERAL SPECIFICATIONS
Nominal battery voltage 12 V 12 V 12 V 12 V 24 V 24 V 24 V 24 V 24 V 24 V 48 V
P30 power Tamb = 25 °C, cos phi 1 500 VA 800 VA 1200 VA 2000 VA 800 VA 1500 VA 2500 VA 5000 VA 10 kVA 15 kVA 2500 VA
Nom. power Tamb = 40 °C, cos phi 1 450 VA 650 VA 1000 VA 1800 VA 650 VA 1200 VA 2000 VA 4000 VA 8 kVA 13 kVA 2000 VA
Peak load 1000 VA 1600 VA 2400 VA 4000 VA 1600 VA 2900 VA 5000 VA 10000 VA 20 kVA 30 kVA 5000 VA
Output waveform true sine true sine true sine true sine true sine true sine true sine true sine true sine true sine true sine
Max. efficiency 91% 92% 92% 92% 92% 92% 92% 90% 92% 92% 92%
Output voltage 230 V, ±5% 230 V, ±5% 230 V, ±5% 230 V, ±5% 230 V, ±5% 230 V, ±5% 230 V, ±5% 230 V, ±5% 230 V, ±5% 230 V, ±5% 230 V, ±5%
Frequency ----------------------- 50Hz, ±0.005% (also available in 60Hz) ---------------------- -------------------------------------------------- 50Hz, ±0.005% (also available in 60Hz) ---------------------------------------------------
Dimensions in mm (hxwxd) 313 x 187 x 82 325 x 220 x 111 340 x 261 x 130 420 x 318 x 130 325 x 220 x 111 340 x 261 x 130 420 x 318 x 130 475.5 x 318 x 254 2x C4 + C5*** 3x C4 + C5*** 420 x 318 x 130
Weight 3.4 kg 3.9 kg 6 kg 9.4 kg 3.9 kg 6 kg 9.7 kg 19 kg 44 kg 55 kg 9.7 kg
Minimum battery capacity >100 Ah >100 Ah >150 Ah >200 Ah >50 Ah >150 Ah >200 Ah >400 Ah >500 Ah >800 Ah >100 Ah
TECHNICAL SPECIFICATIONS
Switch off voltage low battery 10 V, ±0.5 V 10 V, ±0.5 V 10 V, ±0.5 V 10 V, ±0.5 V 19 V, ±0.5 V 19 V, ±0.5 V 19 V, ±0.5 V 19 V, ±0.5 V 19 V, ±0.5 V 19 V, ±0.5 V 36 V, ±0.5 V
Switch on voltage low battery 11 V, ±0.5 V 11 V, ±0.5 V 11 V, ±0.5 V 11 V, ±0.5 V 22 V, ±0.5 V 22 V, ±0.5 V 22 V, ±0.5 V 22 V, ±0.5 V 22 V, ±0.5 V 22 V, ±0.5 V 44 V, ±0.5 V
Switch off voltage high battery 15.5 V, ±0.5 V 15.5 V, ±0.5 V 15.5 V, ±0.5 V 15 V, ±0.5 V 31 V, ±0.5 V 33 V, ±0.5 V 33 V, ±0.5 V 33 V, ±0.5 V 32 V, ±0.5 V 33 V, ±0.5 V 62 V, ±0.5 V
Switch on voltage high battery 14.5 V, ±0.5 V 14.5 V, ±0.5 V 14.5 V, ±0.5 V 14.5 V, ±0.5 V 30 V, ±0.5 V 31 V, ±0.5 V 31 V, ±0.5 V 31 V, ±0.5 V 31 V, ±0.5 V 31 V, ±0.5 V 59 V, ±0.5 V
Max. allowable ripple on DC 5% RMS 5% RMS 5% RMS 5% RMS 5% RMS 5% RMS 5% RMS 5% RMS 5% RMS 5% RMS 5% RMS
Input current (nominal load) 23 A 38 A 42 A 68 A 34 A 70 A 120 A 240 A 4x 120 A 6x 120 A 60 A
No load power consumption:
stand-by mode 43 mA/0.5 W 65 mA/0.8 W 43 mA/0.5 W 50 mA/0.6 W 35 mA/0.8 W 25 mA/0.6 W 25 mA/0.6 W n.a. <10 W, 412 mA <10 W, 412 mA 13 mA/0.7 W
low energy mode (208 V) 300 mA3.6 W 410 mA/4.9 W 420 mA/4.5 W 420 mA/5 W 200 mA/4.9 W 180 mA/4.5 W 225 mA/5.4 W n.a. n.a. n.a. 110 mA/5.4 W
high power mode (230 V) 325 mA/3.9 W 470 mA/5.6 W 450 mA/5 W 480 mA/6 W 240 mA/5.6 W 200 A/5 W 250 A/6 W 250 mA/6 W 150 W 180 W 125 mA/6 W
DC fuse required (slow blow) 100 A 100 A 120 A 240 A 63 A 100 A 160 A 2x 160 A 4x 160 A 6x 160 A 100 A
Minimum DC cable size 16 mm
2
25 mm
2
50 mm
2
70 mm
2
16 mm
2
25 mm
2
50 mm
2
2x 50 mm
2
4x 50 mm
2
6x 50 mm
2
50 mm
2
Harmonic distortion typical 3% 3% 3% 3% 3% 3% 3% 3% 2.5% 2.5% 3%
AC connection (single phase, 3-wire) IEC-1 internal internal internal internal internal internal internal internal internal internal
Cos Phi ------------------------------- all power factors allowed ------------------------------- ----------------------------------------------------------- all power factors allowed ------------------------------------------------------------
OPTIONS
Model C4-RI -------------------- remote control on/off for Mass Sine inverter -------------------- ------------------------------------------------ remote control on/off for Mass Sine inverter ------------------------------------------------
(art. no. 70404110)
Masterlink/MICC ---------------------------------------- battery consumption meter, 12/24 V DC with LCD readout, remote control for Mass Sine inverter and battery charger or Mass Combi ------------------------------------------------- n.a.
System Manager MICC ----------------------------------- battery consumption meter, 12/24 V DC with LCD readout and LED bar, comprehensive remote control for Mass Sine inverter and Mass charger ----------------------------------------- n.a.
(art. no. 70400115)
MasterBus Inverter Interface (art. no. 77030700)
------ suitable for all Mass Sine inverters, available from April 2008 onwards ----- --------------------------------- suitable for all Mass Sine inverters, available from April 2008 onwards ---------------------------------
Universal connection cables for the remote controls: 6 metre - art. no. 6502001030 10 metre - art. no. 6502100100 15 metre - art. no.
6502100150
Transfer system ------ the Masterswitch and Systemswitch can be connected to all inverters ----- --------------------------------- the Masterswitch and Systemswitch can be connected to all inverters ----------------------------------
* Also available for 48 V, art. no. 48/500: 24040500.
** 15% load reduction for the 120 V/60 Hz models.
*** C4 enclosure = 460.6 x 318 x 143 mm, C5 enclosure = 475.5 x 318 x 254 mm (hxwxd).
Mastervolt Guarantee Plan 2-year product warranty worldwide service pure sine wave power galvanic isolation
Overview sine wave inverters - Mass Sine range