Product specifications

3938
Mass Combi Mass Combi Mass Combi Mass Combi Mass Combi Mass Combi Mass Combi Mass Combi
12/1200-60 12/2000-100 12/2500-125 12/4000-200 24/1200-35 24/2000-60 24/2500-75 24/4000-100
Article no. 230 V/50 Hz 36011205 36012005 available April 2008 36014005 36021205 36022005 available April 2008 36024005
Article no. 120 V/60 Hz n.a. 37012005 37014005 n.a. 37022005 37024005
SINE WAVE INVERTER - SPECIFICATIONS
DC input voltage (nominal) 12 V (10 to 15 V) 12 V (10 to 15 V) 12 V (10 to 15 V) 12 V (10 to 15 V) 24 V (20 to 31 V) 24 V (20 to 31 V) 24 V (20 to 31 V) 24 V (20 to 31 V)
Continuous power @ 25˚ C 1200 VA - 5.3 A 2000 VA - 8.7 A 2500 VA - 10.9 A 3750 VA - 16.5 A 1200 VA - 5.3 A 2000 VA - 8.7 A 2500 VA - 10.9 A 3750 VA - 16.5 A
Surge capability (5 sec., resistive) 2400 VA - 10.5 A 4000 VA - 17.5 A 5000 VA - 21.8 A 7500 VA - 32 A 2400 VA - 10.5 A 4000 VA - 17.5 A 5000 VA - 21.8 A 7500 VA - 32 A
Parallel use (to double the power) no yes yes no no yes yes no
Parallel with shore/generator (for more power) yes yes yes yes yes yes yes yes
Output voltage, adjustable via MasterAdjust software 230 V, ±5% 230 V, ±5% 230 V, ±5% 230 V, ±5% 230 V, ±5% 230 V, ±5% 230 V, ±5% 230 V, ±5%
Frequency --------------------- 50 Hz, ±0.003% (60 Hz selectable) --------------------- ---------------------------------------------------- 50 Hz, ±0.003% (60 Hz selectable) -----------------------------------------------------
Output waveform true sine wave true sine wave true sine wave true sine wave true sine wave true sine wave true sine wave true sine wav
Max. efficiency 92% 92% 92% 92% 92% 92% 92% 92%
No load consumption 230 V <9 W <9 W <9 W <9 W <9 W <9 W <9 W <9 W
Search mode consumption + setting range 0.5 W - 40/150 VA 0.5 W - 40/150 VA 0.5 W - 40/150 VA 1 W - 40/150 VA 0.5 W - 40/150 VA 0.5 W - 40/150 VA 0.5 W - 40/150 VA 1 W - 40/150 VA
Dimensions in mm (hxwxd) 371 x 318 x 143 460.5 x 318 x 143 460.5 x 318 x 143 460.5 x 318 x 266 371 x 318 x 143 460.5 x 318 x 143 460.5 x 318 x 143 460.5 x 318 x 266
Weight 7.8 kg 11 kg 11 kg 21 kg 7.8 kg 11 kg 11 kg 21 kg
AUTOMATIC BATTERY CHARGER - SPECIFICATIONS
Input voltage nominal 230 V (180 to 265 V) 230 V (180 to 265 V) 230 V (180 to 265 V) 230 V (180 to 265 V) 230 V (180 to 265 V) 230 V (180 to 265 V) 230 V (180 to 265 V) 230 V (180 to 265 V)
Frequency 45 to 65 Hz 45 to 65 Hz 45 to 65 Hz 45 to 65 Hz 45 to 65 Hz 45 to 65 Hz 45 to 65 Hz 45 to 65 Hz
Max. charge rate (adjustable) 60 A @ 14.25 V 100 A @ 14.25 V 125 A @ 14.25 V 200 A @ 14.25 V 35 A @ 28.5 V 60 A @ 28.5 V 75 A @ 28.5 V 120 A @ 28.5 V
Primary AC consumption (full charge) 1000 VA - 4.4 A 1635 VA - 7.2 A 2045 VA - 8.9 A 3270 VA - 14.4 A 1170 VA - 5.1 A 1965 VA - 8.5 A 2455 VA - 10.7 A 3900 VA - 17 A
Charge voltage @ 25 °C (bulk/float) 14.25/13.25 V 14.25/13.25 V 14.25/13.25 V 28.5/26.5 V 28.5/26.5 V 28.5/26.5 V 28.5/26.5 V 28.5/26.5 V
Battery type settings ------------------- open lead / gel / traction / AGM / spiral ------------------- --------------------------------------------------- open lead / gel / traction / AGM / spiral --------------------------------------------------
Second charge output, 3-step 5 A 5 A 5 A 2x 5 A 5 A 5 A 2x 5 A
Temperature sensor for the battery -------- delivered as standard with 6 metre cable and telejack plug -------- ---------------------------------------- delivered as standard with 6 metre cable and telejack plug ---------------------------------------
DOUBLE POLE TRANSFER SYSTEM
Max. current first output 50 A 50 A 50 A 50 A 50 A 50 A 50 A 50 A
Max. current shortbreak / inverter output 25 A 25 A (35 A @ 120 V) 50 A 25 A (35 A @ 120 V) 25 A 25 A 50 A 25 A (35 A @ 120 V)
Transfer time 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms
GENERAL SPECIFICATIONS
Harmonic distortion (typical) <5% <5% <5% <5% <5% <5% <5% <5%
Temperature range ---------- according specifications: 0 to 25 °C, thereafter derating ---------- ----------------------------------------- according specifications: 0 to 25 °C, thereafter derating -----------------------------------------
Grounding -------------------------- yes, adjustable by DIP switch ------------------------- --------------------------------------------------------- yes, adjustable by DIP switch --------------------------------------------------------
Forced air cooling --------------------------- maintenance free vario fans -------------------------- ---------------------------------------------------------- maintenance free vario fans ---------------------------------------------------------
Listings ---- fully CE and E-marking according Automotive Directive 95/54/EG ---- ------------------------------------ fully CE and E-marking according Automotive Directive 95/54/EG -----------------------------------
REMOTE CONTROL AND MONITORING
Remote ICC optional delivered as standard option: MasterView delivered as standard optional delivered as standard option: MasterView delivered as standard
(art. no. 70405000)
Indication of DC consumption, charge phase, failure and AC availability. With on/off/
charger only switch. Standard equipped with 6 metre cable.
Remote APC optional optional option: MasterView optional optional optional option: MasterView optional
(art. no. 70405010)
Indication of AC consumption, AC voltage and the fuse value of the shore/generator
connection.
Masterlink/MICC optional optional option: MasterView optional optional optional option: MasterView optional
(art. no. 70403105)
Battery consumption meter, 12/24 V DC with LCD readout and remote control for
Mass Sine inverter and battery charger or Mass Combi.
Overview sine wave inverter/charger combinations: Mass Combi series
Mastervolt Guarantee Plan
2-year product warranty worldwide service Mastervolt 3-step charging method pure sine wave power galvanic isolation