Users Manual Part 2

28
MDMAXLITEA
Tap on it to start recording the sample data (*Only data
stream items with units will be recorded), and the screen
displays as below:
Fig. 5-32
Once recording is complete, tap on
to stop it and navigate
to the data revision screen.
Fig. 5-33
Tap on the Min./Max. value to change it. After modifying all
desired items, tap on “Save” to save it as an sample DS file.
All DS files are stored under the “Data Samples” file of “Save
Report” in “Toolbox”.
E. Actuation Test
This option is used to access vehicle-specific subsystem and
component tests. Available test vary by vehicle manufacturer,
year, and model. During the actuation test, the MaxLiteA
tablet outputs commands to the ECU in order to drive the
actuators, and then determines the integrity of the system or
parts by reading the ECU data, or by monitoring the operation
of the actuators, such as switching a injector between two
operating states.
In Fig. 5-23, tap on Actuation Test”, the system will display as
follows:
Fig. 5-34
Simply follow the on-screen instructions and make
appropriate selections to complete the test. Each time when
an operation is successfully executed, “Completed” displays.