User`s manual
Using Control Pins
8-59
fclose([s1 s2])
delete([s1 s2])
clear s1 s2
Controlling the Flow of Data: Handshaking
Data flow control or handshaking is a method used for communicating between 
a DCE and a DTE to prevent data loss during transmission. For example, 
suppose your computer can receive only a limited amount of data before it must 
be processed. As this limit is reached, a handshaking signal is transmitted to 
the DCE to stop sending data. When the computer can accept more data, 
another handshaking signal is transmitted to the DCE to resume sending data.
If supported by your device, you can control data flow using one of these 
methods:
•Hardware handshaking
•Software handshaking
Note Although you may be able to configure your device for both hardware 
handshaking and software handshaking at the same time, MATLAB does not 
support this behavior.
You can specify the data flow control method with the 
FlowControl property. 
If 
FlowControl is hardware, then hardware handshaking is used to control 
data flow. If 
FlowControl is software, then software handshaking is used to 
control data flow. If 
FlowControl is none, then no handshaking is used.
Hardware Handshaking
Hardware handshaking uses specific serial port pins to control data flow. In 
most cases, these are the RTS and CTS pins. Hardware handshaking using 
these pins is described in “The RTS and CTS Pins” on page 8-10.
If 
FlowControl is hardware, then the RTS and CTS pins are automatically 
managed by the DTE and DCE. You can return the CTS pin value with the 
PinStatus property. You can configure or return the RTS pin value with the 
RequestToSend property.