User`s guide
Downsample
5-145
Adjust the block parameters as follows:
•Configure the Signal From Workspace block to generate a two-channel 
signal with frame size of 4 and sample period of 0.25 seconds. This 
represents an output frame period of 1 second (0.25
∗4). The first channel 
should contain the positive ramp signal 1, 2, ..., 100, and the second channel 
should contain the negative ramp signal -1, -2, ..., -100. The settings are:
-
Signal = [(1:100)' (-1:-1:-100)']
- Sample time = 0.25
- Samples per frame = 4
•Configure the Downsample block to downsample the two-channel input by 
decreasing the output frame rate by a factor of 2 relative to the input frame 
rate. Set a sample offset of 1, and a 4-by-2 initial condition matrix of
-
Downsample factor = 2
- Sample offset = 1
- Initial condition = [11 -11;12 -12;13 -13;14 -14]
- Frame-based mode = Maintain input frame size
•Configure the Probe blocks by deselecting the Probe width and Probe 
complex signal
 check boxes (if desired).
This model is multirate because there are at least two distinct frame rates, as 
shown by the two Probe blocks. To run this model in Simulink’s multitasking 
mode, select 
Fixed-step and discrete from the Type controls in the Solver 
11 11–
12 12–
13 13–
14 14–