User`s guide
Frame Status Conversion
5-215
5Frame Status Conversion
Purpose Specify the frame status of the output, sample-based or frame-based.
Library Signal Management / Signal Attributes
Description The Frame Status Conversion block passes the input through to the output, 
and sets the output frame status to the 
Output signal parameter, which can 
be either 
Frame-based or Sample-based. The output frame status can also be 
inherited from the signal at the 
Ref (reference) input port, which is made 
visible by selecting the 
Inherit output frame status from Ref input port 
check box. 
If the 
Output signal parameter setting or the inherited signal’s frame status 
differs from the input frame status, the block changes the input frame status 
accordingly, but does not otherwise alter the signal. In particular, the block 
does not rebuffer or resize 2-D inputs. Because 1-D vectors cannot be 
frame-based, if the input is a length-M 1-D vector, and the 
Output signal 
parameter is set to 
Frame-based, the output is a frame-based M-by-1 matrix 
(i.e., a single channel).
If the 
Output signal parameter or the inherited signal’s frame status matches 
the input frame status, the block passes the input through to the output 
unaltered.
Dialog Box
Inherit output frame status from Ref input port
When selected, enables the Ref input port from which the block inherits the 
output frame status. Tunable.
Output signal
The output frame status, 
Frame-based or Sample-based. Tunable.