User`s guide
Sample Rates and Frame Rates
3-23
The sample period and frame size of the original signal are set to 0.125 seconds 
and 8 samples per frame, respectively, by the 
Sample time and Samples per 
frame
 parameters in the Signal From Workspace block. This results in a frame 
rate of 1 second (0.125
∗8), as shown by the first Probe block.
The Downsample block is configured to downsample the signal by changing the 
frame rate rather than the frame size. The dialog box with this setting is shown 
below.
The second Probe block in the model verifies that the output from the 
Downsample block has a frame period of 2, twice that of the input (i.e., half the 
rate). As a result, the sequence sample period is doubled to 0.25 seconds 
without any change to the frame size.
Example: Rate Conversion by Frame-Size Adjustment. The model from “Example: Rate 
Conversion by Frame-Rate Adjustment” on page 3-22 is shown again below, 
but this time with the rate conversion implemented by adjusting the frame 
size, rather than the frame rate.
Maintain input frame size: 
Downsample the signal by 
changing the frame 
rate
.