User Manual

Page 2
SPECIFICATIONS:___________________________
Sealed handheld enclosure
License free radio (FCC Part 15B)
One month battery life (typical)
Custom labeling available
8 bit controller with 2K flash and CPU watchdog
3 AA batteries give 1 month operation (32 hours continuous)
900MHz one way radio with 8 channels
Operational range of 0 - 300 feet
Internal antenna to prevent damage
Operational temperature range of 0ºC to +70ºC
Storage temperature range of -40ºC to +85ºC
2.75 inches X 1.375 inches X 7 inches, 12.5 oz
Sealed mechanical tactile switches with 1,000,000 cycle switch life
Eight button membrane switch available with 2 digit LED (TP-105)
Optional belt clip and custom labels available
CRC data error checking
APPLICATION:______________________________
Please Note: The TriggerPad 100/105 is not intended for use
as an emergency stop device.
The TriggerPad 100/105 is a transmit on command device. Data is
transmitted from the TriggerPad only when a button is being pressed
by an operator. CRC data error checking and data message identifiers
are used to insure that transmitted data is correctly received and inter-
preted. The transmit on demand feature results in extended battery
life (up to 1 month in most applications). However, without a continu-
ously maintained communication link, the TriggerPad is not appropriate
for applications that require a handheld shutdown for emergency or
safety purposes.
A system level risk assessment should be performed before any new
control application is installed.