User Manual

Page 3
CONFIGURATION:___________________________
Label
There are several standard label configurations available for the Trig-
gerPad, each geared to a typical TriggerPad application. If your appli-
cation requires a unique label, our engineering staff can create a cus-
tom label according to your specifications. Please refer to the Trigger-
Pad configuration sheet to select an off-the-shelf label or to specify a
custom label.
Radio Channel Configuration
The TriggerPad supports eight channels to avoid interaction when mul-
tiple systems are employed in close proximity situations. The radio
channel can be configured at the factory prior to shipment or by a cus-
tomer’s technician in the field. See the configuration sheet to specify a
channel for factory configuration.
*Factory default channel selection
Channel Frequency
0 903.37 MHz
1* 906.37 MHz*
2 907.87 MHz
3 909.37 MHz
4 912.37 MHz
5 915.37 MHz
6 919.87 MHz
7 921.37 MHz
For safety reasons, on site radio channel configuration requires the fol-
lowing basic steps.
1. Power down and lock out any systems that could be operating at
the frequencies shown above.
2. Set the TriggerPad channel. (See instructions below.)
3. Set the channel of the ProComm. (Refer to the appropriate receiver
user manual, i.e. ProComm 100, for receiver configuration.)
4. Return processes and equipment to service.
Please note, to avoid accidentally duplicating channels, it is recom-
mended that the default channel NOT be used in a multi-station appli-
cation.