User Manual

Page 6
INDICATORS:______________________________
The TriggerPad 100 provides 4 red LED indicators. One LED is located
beside each button. These LEDs serve three functions.
First, the LED next to a button will be illuminated when the button is
depressed. This is hardwired visual feedback that the button has been
activated. However, the active button indicator does not show the
status of data transmission.
Second, when no buttons are depressed, the top LED will blink to indi-
cate a low battery condition.
Third, the LEDs are used to indicate the selected channel. See the con-
figuration section for details of channel selection.
The TriggerPad 105 provides a two digit seven segment LED display.
This display is used to set the one byte value that is transmitted with
the switch status from the TP-105. To change the value, press the
“Enter” switch while pressing either the up or down arrow.
BATTERIES:________________________________
The TriggerPad 100/105 uses three standard AA batteries. Depending
upon usage, these batteries should provide up to one month of opera-
tion. A low battery power state will be indicated by a blinking LED as
described in the indicator section.
To replace batteries, simply remove the four corner screws, open the
back half of the enclosure, replace the batteries, and reassemble the
enclosure. The correct battery polarity is marked under the battery
clips.