User Manual Wearable Motion and Gait Quantification Assessment System MA100/MA200-IFU-EN V1.
Revision History Version number Reason for revision and content Date of revision Revisionist V1.0 New Fiction 2022-03-01 Hongyuan Wu V1.
Manufacturer: GYENNO Technologies CO.,LTD. Address: A805 A806,Shenzhen Institute of Industry-University-Research of HUST,No.9 Yuexing 3rd Road,Science Park,Nanshan District,Shenzhen,518000,P.R.China Tel.: 0086-755-86724035 Email: service@gyenno.com Website: www.gyenno.
Table of Contents 1 Intended use .............................................................................................................................7 2 Safety information ...................................................................................................................7 3 Overview ................................................................................................................................... 8 3.1 Introduction ....................................................
.3 Node Wearing ......................................................................................................................18 5.3.1 Node snap-in ........................................................................................................................18 5.3.2 Node pull-out .......................................................................................................................18 5.4 Getting started with the software ....................................................
Description of terms in this manual Warning Caution Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in invalid data collecting ,damage to the equipment or invalid operation. Information necessary to be known before using the equipment.
1 Intended use The Wearable Motion and Gait Quantification Assessment System (hereinafter referred to as "the product") is used for the analysis and assessment of movement symptoms in movement disorders.For patients with movement disorders. 2 Safety information Warning 1. Do not place or store this product near an open flame or heat source. 2. Do not use a broken charging cable or socket. 3. Do not charge this product with a charging base that is not designed for this product. 4.
CAUTION 1. Do not use this product while charging. 2. If the product is accidentally dropped in water or other liquids while charging, please unplug the charging cable immediately, remove the product and wipe it off promptly. 3. If the product is accidentally dropped into water during use, please remove it promptly and wipe it off and allow it to dry completely before using again. 4. Do not use this product in an environment with strong magnetic fields. 5. Do not disassemble or modify this product yourself.
Figure 1 Main Box The Main Box FCC ID :2ACGF-MA00A. 3.2.2 Nodes The nodes is a sensor used to collect motion data. There are 10 nodes marked with letters a – J. During node configuration, the parts worn by each node will be configured. During the collection process, the collection node needs to be worn according to the configuration. Figure 2 Node A-J The Node FCC ID : 2ACGF-MA00B.
3.2.3 Straps This product monitors human activities in real time through the strap wearing collection node. The strap and wearing position are shown in the following figure: Figure 3 Taping 3.2.4 Computer and Camera In addition to the above components, this system requires a PC with the Wearable Motion and Gait Quantification Assessment System PC application installed and a HD camera with USB port. The requirements are shown in the table below.
3.3 Working conditions Conditions Parameters Ambient temperature 0 °C ~ +45 °C Relative humidity 10% ~ 95% (non-condensing) Atmospheric pressure 70kPa ~ 106kPa Table 3 Working conditions 3.4 Transport and storage conditions Conditions Parameters Ambient temperature -25 °C ~ +70 °C Relative humidity 10% ~ 95% (non-condensing) Atmospheric pressure 70kPa ~ 106kPa Table 4 Transport and storage conditions 3.
4 Specifications and parameters 4.1 Specification Products / Components Main chassis Collection Nodes Main parameters Indicators Size Approx340. (L) * 340 (W) * 300 (H) (mm) Weight Approx. 9.5KG Bluetooth Wireless standards BLE Frequency range 2402MHz to 248MHz Type of power supply 5V Data Interface Type-C Number 10 A-J nodes Size ≈ 38.9 (L) * 37 (W) * 12.7 (H) (mm) Weight ≈ 17g Bluetooth 3A Wireless standards BLE Frequency range 2402MHz to 248MHz0 Power supply DC 3.
Charging indicator Blue Flashing Data transfer in progress or being upgraded Red Flashing Equipment exceptions Green Node is fully charged Yellow Any node not filled Table 7 Main Box indicator descriptions 4.2.
5 Instructions for use 5.1 Preparation for use 5.1.1 1 Charging Please insert all nodes into the charging cradle and ensure that the nodes are fully charged before use. Figure 6 Device Charging 5.1.
5.1.3 Venue set-up 1 Please arrange the venue according to the diagram below 2 The distance from the starting point to the return point supports 3-10 metres, the recommended distance is 5 metres 3 Distance from the turning position to the camera is 4 metres 4 The camera should be positioned 2 metres from the return point so that it can capture the whole body of the person being examined Figure 8 Site layout plan 5.2 Strap-on wear 5.2.
5.2.2 Chest strap 1 3 Put your hands through the shoulder straps 2 Adjust the tightness of the shoulder straps. Thinner users Adjust the tightness of chest strap Make sure that the buckle is located between the two ribs, 4 can cross the shoulder straps in an "X" shape on the back the chest strap is parallel to the shoulder, and the buckle opening is facing upward Figure 10 Chest strap after wearing 5.2.
5.2.5 Thigh strap 1 The strap is tied above the knee Adjust the buckle to the outer trouser seam with the 2 buckle opening facing upward Figure 13 Thigh strap after wearing 5.2.6 Ankle strap 1 The strap is tied to the ankle Adjust the buckle to the outer trouser seam line and 2 align with the position of the thigh buckle, and the buckle opening is facing upward Figure 14 Ankle strap after wearing 5.2.
5.3 Node Wearing 5.3.1 Node snap-in Please put the nodes on in the corresponding order. When snapping the nodes in, please note that the side with the numbered letters faces outwards and the nodes are snapped in when you hear a "pop". Do not force the nodes in with the non-slip side facing inwards.
5.4 Getting started with the software 5.4.1 Visit the Wearable Motion and Gait Quantification Assessment System PC application Figure 18 Login software 5.4.
5.4.3 Enter the assessment name and description of the assessment Once the assessment name and description have been saved, they cannot be changed. Please confirm that they are correct before clicking [Next]. Figure 20 Enter the name of the assessment 5.4.4 Add a check a. Click to add a check item b.
5.4.5 Select an assessment template to carry out the assessment Figure 22 Selecting an assessment template 5.4.
5.4.7 Start assessment Once you have entered the assessment, click on [Start Assessment] or use the controller to control the assessment process. Figure 24 Start of assessment 5.4.8 View the assessment report At the end of the assessment, review the assessment conclusions and the parameters of the assessment report. Figure 25 View the assessment report 5.4.
configuration and status query on nodes in [settings] - [node configuration]. 2 Patient management The PC application of wearable movement and gait quantitative evaluation system can view, add and modify patient information in [patient]. 5.5 After use 5.5.1 End of use At the end of use, remove the straps and store them; it is recommended that the straps are cleaned promptly after use. 6 Cleaning and disinfection 6.
humidity and exposure to the sun. 8 Exceptions and their handling Type of fault The main case charging indicator does not light up Possible causes and treatment 1 Verify that the power cable is connected properly 2 If the power cable is connected properly Please call our customer service hotline for solutions. 1 The data cable is not connected. Connect the data cable correctly. The main chassis operating status indicator does not light up 2 Data cable problem.
11 Electromagnetic compatibility information Guidelines and manufacturer's statements - Electromagnetic emissions The Wearable Motion and Gait Quantification Assessment System is intended for use in the following specified electromagnetic environments and the purchaser or user of the Freeze Gait Assist System should ensure that it is used in such environments: Launch test Conformity Electromagnetic Environment - Guide The Freeze Gait Assist uses RF energy only for its internal functions.
GB/T 17626.8 typical of a site in a typical commercial or hospital environment Note: UT refers to the AC network voltage before the test voltage is applied.
13,567 MHz; 26,957 MHz to 27,283 MHz; and 40,66 MHz to 40,70 MHz. The amateur radio bands between 0,15 MHz and 80 MHz are 1,8 MHz to 2,0 MHz, 3,5 MHz to 4,0 MHz, 5,3 MHz to 5,4 MHz, 7 MHz to 7,3 MHz, 10,1 MHz to 10,15 MHz, 14 MHz to 14,2 MHz, 18,07 MHz to 18,17 MHz, 21,0 MHz to 21,4 MHz, 24,89 MHz to 24,99 MHz, 28,0 MHz to 29,7 MHz and 50,0 MHz to 54,0 MHz.
materials This table has been prepared in accordance with the provisions of SJ/T 11364. ○ indicates that the content of the hazardous substance in all homogeneous materials of the component is below the limit specified in GB/T 26572. × Indicates that the content of the hazardous substance in at least one homogeneous material of the component exceeds the limit specified in GB/T 26572.
14 Quality commitment This product comes with a two-year warranty on all nodes and main chassis. Any part of the device, including attachments and accessories, is not allowed to be repaired by unspecified maintenance. One of the following occurs is not eligible for warranty claim: Damaged caused by disassembling or modifing on customer’s own Damage caused by unspecified maintenance by manufacturer. Damaged caused by exceeding the specified conditions of use.