User's Manual
Table Of Contents
- 1Intended use
- 2Safety information
- 3Overview
- 3.1Introduction
- 3.2Product composition
- 3.2.1Main Box
- 3.2.2Nodes
- 3.2.3Straps
- 3.2.4Computer and Camera
- 3.3Working conditions
- 3.4Transport and storage conditions
- 3.5Symbols used in this product
- 4Specifications and parameters
- 4.1Specification
- 4.2 Indicator light description
- 4.2.1Main Box indicator
- 4.2.2Node indicator
- 5Instructions for use
- 5.1 Preparation for use
- 5.1.1Charging
- 5.1.2Device connection
- 5.1.3Venue set-up
- 5.2 Strap-on wear
- 5.2.1Effect after wearing
- 5.2.2Chest strap
- 5.2.3Waist strap
- 5.2.4Wrist strap
- 5.2.5Thigh strap
- 5.2.6Ankle strap
- 5.2.7Vamp strap
- 5.3Node Wearing
- 5.3.1Node snap-in
- 5.3.2Node pull-out
- 5.4Getting started with the software
- 5.4.1Visit the Wearable Motion and Gait Quantification
- 5.4.2New assessment
- 5.4.3Enter the assessment name and description of the a
- 5.4.4Add a check
- 5.4.5Select an assessment template to carry out the ass
- 5.4.6Enter patient information
- 5.4.7Start assessment
- 5.4.8View the assessment report
- 5.4.9Other functions
- 5.5After use
- 5.5.1End of use
- 6Cleaning and disinfection
- 6.1 Cleaning the main chassis and nodes
- 6.2 Cleaning straps
- 7Maintenance and Care
- 8Exceptions and their handling
- 9Cautions
- 10Contraindications
- 11Electromagnetic compatibility information
- 12Name and content of hazardous substances
- 13REGULATORY INFORMATION
- 14Quality commitment
- 15Disposal
- 16Copyright and Responsibility
- 7 -
1 Intended use
The Wearable Motion and Gait Quantification Assessment System (hereinafter referred to as "the product")
is used for the analysis and assessment of movement symptoms in movement disorders.For patients with
movement disorders.
2 Safety information
Warning
1. Do not place or store this product near an open flame or heat source.
2. Do not use a broken charging cable or socket.
3. Do not charge this product with a charging base that is not designed for this product.
4. Do not plug or unplug the charging cable with wet hands.
5. Do not use this product in areas where there are flammable gases and where it can cause an explosion.
6. The user must carry out a safety check on the system before each use and should ensure that the
system is safe to use and works properly.
7. When other devices are connected to the patient's body at the same time, the total amount of leakage
current may exceed the permissible limit and pose a potential danger to the patient.
8. Although all patient contact parts have been tested for biocompatibility, a very small number of people
may have allergic reactions and should be discontinued in patients with allergic reactions.
9. The various accessories of this product must not be replaced at will. If replacement is necessary, the
accessories provided by the company or those of the same type, manufacturer and standard as those
supplied with the product should be used, otherwise there may be adverse consequences in terms of
safety and biocompatibility.
10. If the product is dropped accidentally or if other malfunctions occur, it cannot be used any longer.
11. Repairs are to be carried out only by professional repairers appointed by the manufacturer.
12. Contact with wounds and scars should be avoided.
13. Do not use the instrument in the presence of high voltage equipment, or in an environment with a high
level of static electricity, as this may cause sparks due to momentary discharge.
14. The product must be disposed of in accordance with local regulations or it may cause contamination.
15. When walking with this product, you must be aware of your surroundings.
16. Patients with abnormal gait are at high risk of falls, so please take precautions against falls during the
use of this product.