6.6 ENGINEERING MODE - CLUB ID TAB
ENGINEERING MODE FUNCTION & DEFAULTS DESCRIPTIONS MODIFIED
Club ID This option records the Club ID of
the fitness facility.
N/A
6.7 ENGINEERING MODE - END POINTS TAB
FUNCTION & DEFAULTS DESCRIPTIONS MODIFIED
Tune Incline 1 Top: Top: 2.0 Sets the maximum end incline for incline motor 1. Top: 0.1 - 25.5
Tune Incline 1 Bottom: Bottom: 2.0 Sets the minimum end incline for incline motor 1. Bottom: 0.1 - 25.5
Tune Incline 2 Top: Top: 2.0 Sets the maximum end incline for incline motor 2. Top: 0.1 - 25.5
Tune Incline 2 Bottom: Bottom: 2.0 Sets the minimum end incline for incline motor 2. Bottom: 0.1 - 25.5
ENGINEERING MODE
End Points
CHAPTER 6: ENGINEERING MODE