User`s manual
32
• Transmit [ n] k in ascending order and place a NUL code 0 
at the end. 
• When [ n] k is less than or equal to the preceding value [ n] 
k-1, tab setting is finished and the following data is processed 
as normal data. 
• ESC D NUL cancels all horizontal tab positions. 
• The previously specified horizontal tab positions do not 
change, even if the character width changes. 
• The character width is memorized for each standard and 
page mode. [Default] The default tab positions are at 
intervals of 8 characters (columns 9, 17, 25,...) for font A (12 ´ 
24). 
[Reference] HT 
4.3.3 ESC \ nL nH   
[Name]: Set relative printing position   
[Format]:  ASCII      ESC  \  nL nH 
Hexadecimal  1B   5C nL nH 
Decimal    27   92 nL nH 
[Range]: 0 ≤ nL ≤ 255; 0 ≤ nH ≤ 1. 
[Description]: Sets the print starting position based on the 
current position by using the horizontal or vertical motion unit. 
This command sets the distance from the current position to 
n [( nL + nH × 256)horizontal motion unit] 
[Notice]: 
• Any setting that exceeds the printable area is ignored. 










