Specifications

15
Installation,OperationandMaintenanceManual
MatrixxMX-100,MX-150,MX-200System
DiagnosticsMode
1.Ifscreenislocked,press“MENU”for3secondstounlock.
2.PressandholdtheUPandDOWNbuttonsforthreesecondstoenterLevelDiagnosticsMode.
Inthismode,keydiagnosticscanbeviewedfortroubleshootingandproblemsolving.Inaddition,theval
uescanberesettozeroindividuallybypressing“SET/REGEN”for3seconds
PARAMETER
DESCRIPTION
LASTREGEN
Thisvalueisthedatethevalvelastperformedaregenerationcycle.
TOTALREGENS
Totalperformed.
METERTOTAL
Thisvalueisthetotalnumberofgallonsthesystemhastreated.
CURRENTFLOWRATE
CURRENTREFILL
ThisisthecurrentvalueoftheREFILLcalculation.
CAPACITY
ThisisthecurrentvalueoftheCAPACITYcalculation.
REGEN.DAYS
ThisisthecurrentvalueoftheREGEN.DAYScalculation.
PEAKFLOWRATE
Thisisthehighestflowrate(inGPM)recordedbythevalvesflowmeterinthepast48hours.
SOFTWAREVER.
Thisisthecurrentversionofsoftware.
Thisisthecurrentflowrateoftheunit.
VacationSettingsMode
1.Ifscreenislocked,press“MENU”for3secondstounlock.
2.PresstheDOWNarrowfor3secondstoentertheVacationSettingsMode.Inthismodethelengthoftimeforbackwashandrinse
alongwiththefrequencyaresetwhilethevalveisinvacationmode.
PARAMETER
DESCRIPTION
REGEN.DAYS
Thisvalueisthefrequencyofhowoftentheunitshouldperformabriefbackwashandrinse.
BACKWASH
Thisoptioncontrolsthelengthoftimeinminutesfortheunittobrieflycleanthebedbyreversingtheflowofwater
upwardsthroughthebedandouttothedrain.
RINSE
Thisoptioncontrolsthelengthoftimetogivethetankabriefrinsefromthetoptothebottominordertoremoveany
staleorstagnantwaterfromthetank.