Specifications

3
SystemSpecifications
Figure1.Specifications
US Water Systems classifies each softener according to the actual resin capacity. However, this is not the
regeneration capacity. The regeneration capacity will be lower than the actual resin capacity. This is due to
the resin s regeneration salt curve. For example:
A 53,000 grain unit would require 30 lbs of salt during regeneration if the capacity was set to the actual resin
capacity ( 53,000 grains ) . If the unit is set at 37,000 grains it can be regenerated using only 10 lbs of salt.
The unit is much more efficient when it is set using the proper salt curve capacity and salt dosage levels. So
you can see that to get the final 16,000 grains from a 53,000 grain unit the salt usage will more than double.
Please use the chart below when setting you softener. This will ensure efficiency and longevity of your unit.
 MaximumWaterTemperature=110°F(43°C)
 MaximumOperatingPressure=100
PSIG(689kPa)
 Voltage=110voltsstandard
 PipeSize=3/4”
 At the stated service flow rates, the pres
sure drop through these devices will not
exceed15psig.
 Changingsaltsettingsfromfactory setting
may require changing injector sizes to
achievestatedcapacities.
 Themanufacturerreservestherighttomake
productimprovementswhichmaydeviatefrom
thespecificationsanddescriptionsstatedherein,
withoutobligationtochangepreviouslymanufac
turedproductsortonotethechange.
Model# SystemCapacityGrains FlowRate RegenerationWater Mineral
Tank
Size
Resin
Cu.Ft.
BrineTank/
Cabinet
SizeInches
Salt
Capacity
(Lbs)
Ship
Weight
(Lbs)
@10
lbs/cuft
@6lbs/
cuft
(Factory
Settings)
@3lbs/
cuft
Service
USGPM
Back
wash
USGPM
Clean
Water
(Factory
Setting)
Problem
Water
085-MX-100 25,000 20,000 13,000 10.0 2.0 38.0 48.0 9X48 1.00 15X15X
34.7
230 122
085-MX-150 37,000 30,000 18,000 12.0 2.4 48.5 60.5 10X54 1.50 15X15X
34.7
230 155
085-MX-200 50,000 40,000 25,000 15.0 3.5 80.5 95.5 12X52 2.00 20.3X37.4 385 158
Installation,OperationandMaintenanceManual
MatrixxMX-100,MX-150,MX-200System
FortheHTOsystemsusethefollowingchart.
24,000
37,000 44,000
4.7
7.1 9.5