Product information
Specifications
Avio F120
Environmental
Power consumption and supply voltage
Transmitter Receiver
Monitors supported 2 single-link or 1 dual-link 2 single-link or 1 dual-link
Supported resolutions All single-link DVI and dual-link DVI resolutions
Video input connectors 2
× DVI-D
Video output connectors 2
× DVI-I
2
× DVI-I
Dimensions 21.59 cm × 4.19 cm × 13.56 cm / 8.5" × 1.65" × 5.34"
Laser emissions 850 nm laser compliant to 21CFR, Subpart J, Class 1
EMC Certifications Class A: ACMA, CE, FCC, VCCI, Korean notice
Temperature, operational 5 to 40 ºC (41 to 104 ºF)
Temperature, non-operational
storage and transportation
-40 to 70 ºC ( -40 to 158 ºF)
Humidity, operational (indoor) 20 to 80% (non-condensing)
Humidity, non-operational storage
and transportation
5% to 95% (non-condensing)
Atmospheric pressure, operational
650hPa (3,580 meters / 11,745 feet)
to 1013hPa (0 meters / 0 feet)
Atmospheric pressure,
non-operational and transportation
192hPa (12,000 meters / 39,370 feet)
to 1020hPa (-50 meters / -164 feet)
Avio F120 unit
Power requirements
12V DC, maximum 2.5 A
(2.5 A fuse for overcurrent protection)
Power connector DIN 4 female (4-pin)