No. P-JHC-E006 DATE 2016-05 PRODUCTS DATA SHEET MICRO FUSE TYPE JHC SIZE 7.3x5.8mm UL. cUL approved File No.E170721 30A,40A,50A,60A RoHS compliant 〈Complete lead-free〉 MATSUO ELECTRIC Co., LTD.
(P-JHC-E006) Type JHC TYPE JHC High Current Micro Fuse is designed for the purpose of external short circuit protection of the lithium ion battery of medium sizes, such as a power tool and an electric assistant bicycle. Though it was a surface mount type, it was small and realized high current rating, because a fuse element and a terminal adopt the structure of one. Furthermore perfectly compliant to Lead-free makes environment friendly design. FEATURES 1.
ORDERING INFORMATION JHC Type JHC Code 3502 6002 3502 Voltag e 35V 60V 503 Case size Rated current Code Rated current Code Package type Code Case size 303 403 503 30 A 40 A 50 A 603 803 104 60 A 80 A 100 A R N φ180 Reel φ330 Reel 44E 7.3X5.8 AND RATING Rated current A Internal resistance mΩ (Typical) 30 1.38 40 1.08 50 0.85 60 0.
PERFORMANCE No Performance Item Test method Temperature rise shall not exceed 75℃ 1 Temperature rise 2 Current-carrying capacity Shall not open within 1 hour. Apply rated current Apply 100% of rated current 3 Clearing characteristics Arc shall not be continued. No ignition. Marking shall be legible No bursting of the fuse 4 Voltage drop Voltage drop is below the value specified in CATALOG NUMBERS AND RATING. Apply rated current 5 Fusing characteristics Fusing within I min.
Reference Reference 40A 60A 100A 30A 50A 80A 100 10000000 100A 80A 60A 50A 40A 30A 1000000 10 Joule Integral (A2・s) 100000 Fusing time (s) 1 0.1 10000 1000 参考値 参考値 100 0.01 10 0.001 10 100 1 0.001 1000 0.01 0.1 1 10 100 Applied Current (A) Fusing time (s) DISTRIBUTION OF FUSING CHARACTERISTICS DISTRIBUTION OF FUSING TIME 100 100 10 Fusing time (s) Fusing time (s) 10 1 1 250% rated current is applied 0.1 0.01 400% rated current is applied 0.1 0.
Determine the rated value of the micro fuse, and select the micro fuse for your circuit. If you select the micro fuse , safety of your circuit can be ensured. How to determine the rated value of the micro fuse is described below: ■Flow for fuse selection 1. Measurement of circuit values using actual device Measure the circuit values, such as operating current of the circuit. 2.
Calculation using Formula 1 : Rated current ≥ 30/(0.90×0.94) = 35.5A The above calculation result shows that the fuse with rated current of 35.5A or more should be selected for this circuit. Type JHC, with rated current of 50 A and 40A can be selected. 3. Calculation from overload current 3–1 Measurement of overload current Using oscilloscope or equivalents, measure overload current that needs to break circuit.
(generally 100,000 times) ②Obtain load ratio from Pulse resistance characteristics. (Fig. D) Example : 100,000 times is required against inrush current applied. The load ratio is 35% or less from Fig. D. Fig. D 1000000 Number of resistance (cycle) 100000 10000 1000 100 10 0 10 20 30 40 50 60 70 80 90 100 Load ratio (%) 4–5 Calculation from Joule integral and load ratio Use Formula 4 to calculate the standard I2t for the fuse to be used. Standard I2t of fuse > (I2t of inrush current/load ratio) ...