Use and Care Manual

8
Residential Ultraviolet Sterilization Systems
Electronic Ballast Quartz Sleeve Lamp
BEB-2439
QS32
GL32PP
PARTS & ACCESSORIES
Addional Accessories Specic to Your UV System
UV-NUT-1 /
UV-NUT-2
UV-32SPRING
UV-SEAL
UV-WASHER
UV-PLUG
UVA-8C
12
Electronic Ballast Quartz Sleeve Lamp
BEB-2439
QS39
GL39PP
PARTS & ACCESSORIES
GPM
Rated Life
(hours)
Lamp Was
Voltage @
50/60HZ
Visual
Warning
Audible
Warning
Number of
Lamps
Port Size
Inlet/Outlet
Water
Chamber
Length Width
Maximum
Pressure
Working
Temp.
Wavelength Microjoules
8
9,000
32W
110V/220V
LED
INDICATOR
W/ALARM
1
3/4” MNPT
STAINLESS
304
27.87”
2.5”
125 PSI
35
o
F
-
104
o
F
254 nm
30 mJ/cm
2
GPM
Rated Life
(hours)
Lamp Was
Voltage @
50/60HZ
Visual
Warning
Audible
Warning
Number of
Lamps
Port Size
Inlet/Outlet
Water
Chamber
Length Width
Maximum
Pressure
Working
Temp.
Wavelength Microjoules
12
9,000
39W
110V/220V
LED
INDICATOR
W/ ALARM
1
3/4” MNPT
304
36.81”
2.5”
125 PSI
35
o
F
-
104
o
F
254 nm
30 mJ/cm
2
Addional Accessories Specic to Your UV System
UV-NUT-1 /
UV-NUT-2
UV-39SPRING
UV-SEAL
UV-WASHER
UV-PLUG
UVA-12C
A A
Manufacturer’s
Standard
NSF/EPA
Standard
E. coliE. coli
eradicatederadicated
at 6.6 mJ/cm
at 6.6 mJ/cm
2
2
Cryptosporidium
Cryptosporidium
Cryptosporidium Cryptosporidium
Cryptosporidium
& Giardia Lamblia
& Giardia Lamblia
& Giardia Lamblia
& Giardia Lamblia
& Giardia Lamblia
eradicated at
eradicated at
eradicated ateradicated at
eradicated at
<10 mJ/cm
<10 mJ/cm
2
2
U
V
A
-
1
2
C
U
V
A
-
8
C
U
V
A
-
6
C
U
V
A
-
2
C
1966
Public Health
Note: Dosages based on 95% UVT at end of lamp life (EOL)
Note: 1 mJ/cm2 = 1,000 µ
2
Wsec/cm
2
U
V
A
-
1
C
6.5 gpm at
6.5 gpm at
6.5 gpm at
6.5 gpm at
recommended
recommended
recommended
recommended
UV dose of
UV dose of
UV dose of
UV dose of
40 mJ/cm
40 mJ/cm
40 mJ/cm
40 mJ/cm
40 mJ/cm
40 mJ/cm
40 mJ/cm
2
2
8 gpm at
8 gpm at
8 gpm at
8 gpm at
recommended
recommended
recommended
recommended
recommended
UV dose of
UV dose of
UV dose of
UV dose of
30 mJ/cm
30 mJ/cm
30 mJ/cm
30 mJ/cm
2
15 gpm at
15 gpm at
15 gpm at
15 gpm at
15 gpm at
recommended
recommended
recommended
recommended
recommended
recommended
UV dose of
UV dose of
UV dose of
UV dose of
UV dose of
16 mJ/cm
16 mJ/cm
2
U
V
A
-
4
C
Manufacturer’s
Standard
NSF/EPA
Standard
E. coliE. coli
eradicatederadicated
at 6.6 mJ/cm
at 6.6 mJ/cm
2
2
Cryptosporidium
Cryptosporidium
Cryptosporidium Cryptosporidium
Cryptosporidium
& Giardia Lamblia
& Giardia Lamblia
& Giardia Lamblia
& Giardia Lamblia
& Giardia Lamblia
eradicated at
eradicated at
eradicated ateradicated at
eradicated at
<10 mJ/cm
<10 mJ/cm
2
2
U
V
A
-
1
2
C
U
V
A
-
8
C
U
V
A
-
6
C
U
V
A
-
2
C
1966
Public Health
Note: Dosages based on 95% UVT at end of lamp life (EOL)
Note: 1 mJ/cm2 = 1,000 µ
2
Wsec/cm
2
U
V
A
-
1
C
9 gpm at
9 gpm at
9 gpm at
recommended
recommended
recommended
UV dose of
UV dose of
UV dose of
40 mJ/cm
40 mJ/cm
2
2
12 gpm at
12 gpm at
12 gpm at
recommended
recommended
recommended
recommended
UV dose of
UV dose of
UV dose of
30 mJ/cm
30 mJ/cm
30 mJ/cm
2
23 gpm at
23 gpm at
23 gpm at
23 gpm at
23 gpm at
recommended
recommended
recommended
UV dose of
UV dose of
UV dose of
16 mJ/cm
16 mJ/cm
16 mJ/cm
16 mJ/cm
16 mJ/cm
2
2
U
V
A
-
4
C