Instructions / Assembly

Specifications
Part Number
GPM
(LPM)
Rated Life
(hrs)
Lamp
Watts
Voltage at
50/60HZ
Visual
Warning
Audible
Warning
# of
Lamps
Port Size
I/O
Water
Chamber
Timer Length Width
Max.
Pressure
Working
Temp.
Wavelength Microjoules
UVA- 1C
1
(3.8)
9,000 10W 110V/220V LED BUZZER 1
1/4” MNPT
(.635 cm)
STAINLESS 304 -
10.47”
(26.594 cm)
2”
(5.080 cm)
125 PSI
8.79 kgF/cm
2
35
F
-
104
F
(1.67
C
-
40
C)
254 nm 30 mJ/cm
2
UVA-2C
2
(7.57)
9,000 14W 110V/220V LED BUZZER 1
1/4” MNPT
(.635 cm)
STAINLESS 304 -
13.74”
(34.900 cm)
2.5”
(6.350 cm)
125 PSI
8.79 kgF/cm
2
35
F - 104
F
(1.67
C
-
40
C)
254 nm 30 mJ/cm
2
UVA-4C
4
(15.14)
9,000 17W 110V/220V LED BUZZER 1
1/2” MNPT
(1.270 cm)
STAINLESS 304 -
15.50”
(39.37 cm)
2.5”
(6.350 cm)
125 PSI
8.79 kgF/cm
2
35
F - 104
F
(1.67
C
-
40
C)
254 nm 30 mJ/cm
2
UVA-6C
6
(22.71)
9,000 24W 110V/220V LED
INDICATOR W/ ALARM
1
1/2” MNPT
(1.270 cm)
STAINLESS 304 -
23.23”
(59.00 cm)
2.5”
(6.35 cm)
125 PSI
8.79 kgF/cm
2
35
F - 104
F
(1.67
C
-
40
C)
254 nm 30 mJ/cm
2
UVA-8C
8
(30.28)
9,000 32W 110V/220V LED
INDICATOR W/ ALARM
1
3/4” MNPT
(1.905 cm)
STAINLESS 304 -
27.87”
(70.79 cm)
2.5”
(6.35 cm)
125 PSI
8.79 kgF/cm
2
35
F - 104
F
(1.67
C
-
40
C)
254 nm 30 mJ/cm
2
UVA-12C
12
(45.42)
9,000 39W 110V/220V LED
INDICATOR W/ ALARM
1
3/4” MNPT
(1.905 cm)
STAINLESS 304 -
36.81”
(93.50 cm)
2.5”
(6.35 cm)
125 PSI
8.79 kgF/cm
2
35
F - 104
F
(1.67
C
-
40
C)
254 nm 30 mJ/cm
2
UVA-24B
24
(90.85)
9,000 39W 110V/220V LED
INDICATOR W/ ALARM
2
1” MNPT
(2.540 cm)
STAINLESS 304
36.93”
(93.80 cm)
3.5”
(8.89 cm)
125 PSI
8.79 kgF/cm
2
35
F - 104
F
(1.67
C
-
40
C)
254 nm 30 mJ/cm
2
UVA-36B
36
(136.27)
9,000 39W 110V/220V LED
INDICATOR W/ ALARM
3
1.5” MNPT
(3.810 cm)
STAINLESS 304
36.93”
(93.80 cm)
5.5”
(13.97 cm)
125 PSI
8.79 kgF/cm
2
35
F - 104
F
(1.67
C
-
40
C)
254 nm 30 mJ/cm
2
UVA-50B
50
(189.27)
9,000 39W 110V/220V LED
INDICATOR W/ ALARM
4
1.5” MNPT
(3.810 cm)
STAINLESS 304
36.93”
(93.80 cm)
5.5”
(13.97 cm)
125 PSI
8.79 kgF/cm
2
35
F - 104
F
(1.67
C
-
40
C)
254 nm 30 mJ/cm
2
UVA-60B
60
(227.12)
9,000 39W 110V/220V LED
INDICATOR W/ ALARM
5
2” or 2.5”
(5.080 or 6.350 cm)
FLANGE
STAINLESS 304
36.93”
(93.80 cm)
5.5”
(13.97 cm)
125 PSI
8.79 kgF/cm
2
35
F - 104
F
(1.67
C
-
40
C)
254 nm 30 mJ/cm
2
UVA-80B
80
(302.83)
9,000 39W 110V/220V LED
INDICATOR W/ ALARM
6
2” or 2.5” MNPT
(5.080 or 6.350 cm)
FLANGE
STAINLESS 304
36.93”
(93.80 cm)
6.26”
(15.90 cm)
125 PSI
8.79 kgF/cm
2
35
F - 104
F
(1.67
C
-
40
C)
254 nm 30 mJ/cm
2
UVA-100B
100
(378.54)
9,000 39W 110V/220V LED
INDICATOR W/ ALARM
8
2” or 2.5” MNPT
(5.080 or 6.350 cm)
FLANGE
STAINLESS 304
36.93”
(93.80 cm)
8.62”
(21.90 cm)
125 PSI
8.79 kgF/cm
2
35
F - 104
F
(1.67
C
-
40
C)
254 nm 30 mJ/cm
2
UVA-150B
150
(567.81)
9,000 87W 110V/220V LED
INDICATOR W/ ALARM
6
3” MNPT
(7.62 cm) FLANGE
STAINLESS 304
36.93”
(93.80 cm)
8.62”
(21.90 cm)
125 PSI
8.79 kgF/cm
2
35
F - 104
F
(1.67
C
-
40
C)
254 nm 30 mJ/cm
2
UVA-200B
200
(757.08)
9,000 87W 110V/220V LED
INDICATOR W/ ALARM
8
4” MNPT
(10.16 cm) FLANGE
STAINLESS 304
36.93”
(93.80 cm)
8.62”
(21.90 cm)
125 PSI
8.79 kgF/cm
2
35
F - 104
F
(1.67
C
-
40
C)
254 nm 30 mJ/cm
2
Parts & Accessories
Part Number Lamp Quartz Sleeve Electronic Ballast Additional Accessories Specific to Your UV System
UVA- 1C GL10PP QS10 BEB-1024 UV-NUT-1 - - UV-SEAL UV-WASHER -
UVA-2C GL14PP QS14 BEB-1024 UV-NUT-1 - - UV-SEAL UV-WASHER -
UVA-4C GL17PP QS17 BEB-1024 UV-NUT-1 - - UV-SEAL UV-WASHER -
UVA-6C GL24PP QS24 BEB-2439 UV-NUT-1/ UV-NUT-2 - - UV-SEAL UV-WASHER UV-PLUG
UVA-8C GL32PP QS32 BEB-2439 UV-NUT-1/ UV-NUT-2 UV-32 SPRING - UV-SEAL UV-WASHER UV-PLUG
UVA-12C GL39PP QS39 BEB-2439 UV-NUT-1/ UV-NUT-2 UV-39 SPRING - UV-SEAL UV-WASHER UV-PLUG
UVA-24B GL39PP QS39 ZEB-2439 UV-NUT-1/ UV-NUT-2 UV-39 SPRING UV-TIMER UV-SEAL UV-WASHER UV-PLUG
UVA-36B GL39PP QS39 ZEB-2439 UV-NUT-1/ UV-NUT-2 UV-39 SPRING UV-TIMER UV-SEAL UV-WASHER UV-PLUG
UVA-50B GL39PP QS39 ZEB-2439 UV-NUT-1/ UV-NUT-2 UV-39 SPRING UV-TIMER UV-SEAL UV-WASHER UV-PLUG
UVA-60B GL39PP QS39 ZEB-2439 UV-NUT-1/ UV-NUT-2 UV-39 SPRING UV-TIMER UV-SEAL UV-WASHER UV-PLUG
UVA-80B GL39PP QS39 ZEB-2439 UV-NUT-1/ UV-NUT-2 UV-39 SPRING UV-TIMER UV-SEAL UV-WASHER UV-PLUG
UVA-100B GL39PP QS39 ZEB-2439 UV-NUT-1/ UV-NUT-2 UV-39 SPRING UV-TIMER UV-SEAL UV-WASHER UV-PLUG
UVA-150B GL87PP QS39 ZEB-55155 UV-NUT-1/ UV-NUT-2 UV-39 SPRING UV-TIMER UV-SEAL UV-WASHER UV-PLUG
UVA-200B GL87PP QS39 ZEB-55155 UV-NUT-1/ UV-NUT-2 UV-39 SPRING UV-TIMER UV-SEAL UV-WASHER UV-PLUG
Distributed by:
Product Ratings
RoHS
COMPLIANT
Warranty Information
Limited 5-year warranty on stainless steel housing
Limited 1-year warranty on electronics
Water Quality
Water quality plays a major role in the transmission
of germicidal ultraviolet rays. It is recommended
that the water does not exceed the following
maximum concentration levels.
Maximum Concentration Levels
Eectively treating water with higher concentration
levels than listed
above can be accomplished, but may require added measures to
improve water quality to treatable levels.
UV Dose
The units generate a UV dosage of at least 30,000
microwatt-seconds per square centimeter
(µW-s/cm
2
), even at the end-of-lamp life (EOL),
which is more than sucient to destroy most
waterborne microorganisms, such as bacteria,
yeasts, algae, etc.
UV disinfection is aected by many factors and
the following should be looked at prior to the
installation of the UV system; UV Transmission
(transmittance) deals with the eectiveness in
which the 2537 Angstrom units (254 nanometers)
wavelength of the ultraviolet light is transmitted
through the water. The higher the transparency
of the water, the more eective the UV system
becomes. This optical clarity is evaluated by
performing a test which passes through a 1 cm depth.
Iron < 0.3 ppm (0.3 mg/L)
Hardness < 7 ppm (120 mg/L)
Turbidity < 1 NTU
Manganese < 0.05 ppm (0.05 mg/L)
Tannins < 0.1 ppm (0.1 mg/L)
UV Transmittance > 75%
The basic design of the units has taken into
account a typical transmission at the desired
wavelength. In practical terms this means that
a system designed to ow at 24 gallons per
minute, at a typical transmissibility could actually
have a higher ow rate in liquids with a higher
transmissibility. As a general guideline, the
following are some typical UV transmission
rates (UVT):
City water supplies 85-98%
Deionized or RO water 95-98%
Surface waters (lakes, rivers, etc) 70-90%
Ground water (wells) 90-95%
Other liquids 1-99%
P.O. Box 2235
Chino Hills, CA 91709 USA
OVERLAP FLIP 0.5”
LIT-PSUV-CAT16 05/25/16
©2016 POLARIS SCIENTIFIC UV. All Rights Reserved.
Folding Guide
Cut Guide
FOLD
HERE
FOLD
HERE
FOLD
HERE
FOLD
HERE
Gate Fold Cover.indd 1 5/25/16 12:49 PM