Positive Displacement Flowmeters Operational Manual Model G004 Model G015 For Models G004, G015, G045, G105, G240 Model G045 Model G240 Model G105 Gear - G Series Positive Displacement Flow Meters Max Machinery, Inc. G Series User Manual © Copyright 2013 Rev.
Table of Contents Before You Install................................................................................... page 3 Meter General Description................................................................... page 4 Transmitter General Description........................................................ page 5 Meter Specifications............................................................................. page 6 Transmitter Specifications...........................................................
Before You Install Thank you for choosing to install a Max Machinery precision flow meter. To ensure the best experience please take a moment to read through this manual prior to installation. When you purchased this meter a flow engineer helped determine the best meter for you based on many of the factors that will be reviewed on the following pages. If you have any questions about installation or operation please don't hesitate to call Max Machinery, Inc.
Meter General Description The G-Series flow metering systems are the combination of a high pressure gear meter and a high resolution, microprocessor based transmitter. While gear meters are traditionally based on a design similar to a conventional hydraulic pump, the G Series of flow meters has been engineered to increase signal resolution, prevent internal cavitation and greatly reduce the pressure drop required to move fluid through the gears.
Transmitter General Description Max transmitters are designed to work with the entire family of Max Flow Meters to provide extremely precise flow measurement in a cost effective package. Different options of industrial housings or IP66 rated explosion proof enclosures, combined with a choice of one-part and two-part, high temperature designs with remote electronics cover a wide range of application environments – from the laboratory to harsh industrial processes.
Meter Specifications Model G004 G015 G045 G105 G240 Maximum flow rate Liters/min: 4 15 45 105 240 Gal/min: 1 4 11.9 28 64 Maximum pressure (psi) |-----------------------425 bar (6000 psi)-----------------------| see below 2 Maximum temperature --------------------- 2 part: 225°C (435°F) -------------------- 3 Recommended filtration 10 micron 15 micron 20 micron 20 micron 30 micron Displacement (cc/rev) 1.8 4.2 13.5 38 133 Weight (kg) 1.2 1.8 3.7 7.
Transmitter Specifications Supply Voltage & Current Frequency output Analog output 5-26 Vdc @ 30 mA typical 12Vdc @ 90 mA typical 24Vdc @ 45 mA typical Analog Resolution Adjustable without recalibration to any range of +/- 20mA - Models ending in “A1” and “B1” +/- 10 Vdc - Models ending in “C1” and “D1”) FREQUENCY MODEL SPECIFICATIONS Output (5.0 Volt Supply) No Load 0.00 / 4.80 Volts 2.5K Load to Common 0.00 / 4.60 Volts 2.5K Load to +5 Volts 0.25 / 4.
Transmitter Specifications Temperature graph Model 29X Transmitter Series 120 110 Ambient Temperature °C 100 80 60 295 & 296 Standard 40 296 High temperature 2 part pickup 295 & 296 Ultra High temperature 2 part pickup 20 0 -25 50 100 150 200 Process Temperature °C Max Machinery, Inc. G Series User Manual © Copyright 2013 Rev.
Do’s & Don’ts DO: Install bypass plumbing around the flow meter. This is useful during start up for removing dirt and air from the plumbing or when measuring fluid that may freeze inside the line and need to be remelted before it can pass through the meter. It also allows removing the flow meter for service without disabling the system. DO: Install the meter on its side. DO: Be very careful to keep parts clean during installation or teardown.
Installation Prior to installing the flow meter remove the storage caps from the ports and look carefully into each port of the meter. Ensure that no dirt or foreign particles have gotten into the ports of the meter. Make sure that adequate filtration exists upstream of the flow meter and that no contaminants exist in the line between the filter and flow meter. It is recommended that the flow meter be connected to the circuit by means of unions close to the flow meter to allow easy removal.
Piping Diagram Horizontal Installation Vertical Installation FLOW FLOW METER VALVE 1 VALVE 2 VALVE 2 FILTER VALVE 3 BYPASS FLOW METER Horizontal Two-Way Flow VALVE 3 BYPASS FLOW FLOW METER VALVE 1 FILTER VALVE 2 FILTER FILTER VALVE 3 VALVE 1 FLOW BYPASS Operation Determine that the following parameters of your flow metering system are within the specifications for the specific meter being used: Maximum System Pressure (Specifications) Differential Pressure across meter (Pressure Drop Curv
Electrical Installation - Wiring Removal note: The transmitter does not need to be removed from the flow meter for any field servicing or adjustments. Normally, the flow meter and transmitter are shipped back to the factory for calibration or service as a unit. If the transmitter needs to be removed from the flow meter for installation, be sure to retighten the transmitter snugly in order to ensure proper sensor alignment. Mechanical Installation 1.
Electrical Installation - Wiring Wiring FREQUENCY The electrical connector versions are pre-wired inside the transmitter and ready to accept a mating cable (available from the factory).
Troubleshooting Trouble Corrective Action No Flow through meter or high pressure drop across meter Solidified material blocking rotation Heat meter to melt material Debris blocking rotation Flush the inside of the meter and try to work the gear free by displacing debris If you find damaged parts in the meter, return the meter to the factory for repair Meter broken Fluid is passing through the meter, but there is no indication of flow Improper hook-up of transmitter Verify that DC power is present a
Model G004 Flow Meter 2.26” (57mm) 1.93” (49mm) 1/2” NPT 3.70” 4.09” (94mm) (104mm) 1.75” 1.75” (45mm) (45mm) 1/8” NPT 1/8" NPT 1/8” NPT 1/8" NPT MODEL G004 WITH INDUSTRIAL HOUSING TRANSMITTER MODEL G004 WITH EX-PROOF HOUSING TRANSMITTER 2.75” 2.26” (70mm) (57mm) 2.26” (57mm) 2.6” (66mm) 0.65” mounting holes 1/4” - 20NC (4) places (17mm) not to scale 1.
Model G015 Flow Meter 2.26” (57mm) 1.93” (49mm) 1/2” NPT 4.33” 3.94” (110mm) (100mm) 2.0” 2.0” (51mm) (51mm) 3/8” NPT 3/8” NPT 1/8" NPT MODEL G015 WITH EX-PROOF HOUSING TRANSMITTER MODEL G015 WITH INDUSTRIAL HOUSING TRANSMITTER 3.23” (82mm) 2.26" (57mm) 2.26" 3.07” (57mm) (78mm) mounting holes 1/4” - 20NC (4) places 0.65" (17mm) not to scale 1.
Model G045 Flow Meter 2.26” (57mm) 1.93” (49mm) 1/2” NPT 4.84” 4.45” (123mm) (113mm) 2.52” (64mm) 2.52” (64mm) 1/8" NPT 1/8" NPT 1/2” NPT 1/2” NPT MODEL G045 WITH EX-PROOF HOUSING TRANSMITTER MODEL G045 WITH INDUSTRIAL HOUSING TRANSMITTER 3.98” 2.26” (101mm) (57mm) 2.26” (57mm) 3.82” (97mm) 0.65” (17mm) mounting holes 1/4” - 20NC (4) places not to scale EX-PROOF HOUSING TOP VIEW 2.
Model G105 Flow Meter 2.26” (57mm) 1.93” (49mm) 1/2” NPT 5.67” 5.28” (144mm) (134mm) 3.35” 3.35” (85mm) (85mm) 3/4” NPT 3/4” NPT MODEL G105 WITH INDUSTRIAL HOUSING TRANSMITTER MODEL G105 WITH EX-PROOF HOUSING TRANSMITTER 4.96” 2.26” (126mm) (57mm) 2.26” (57mm) 4.72” (120mm) 0.65” (17mm) mounting holes 1/4” - 20NC (4) places not to scale EX-PROOF HOUSING TOP VIEW 2.
Model G240 Flow Meter 2.26” 1.93” (57mm) (49mm) 1/2” NPT 7.13” 6.73” (181mm) (171mm) 4.80” 4.80” (122mm) (122mm) 1” NPT 1” NPT MODEL G240 WITH INDUSTRIAL HOUSING TRANSMITTER MODEL G240 WITH EX-PROOF HOUSING TRANSMITTER 6.69” 2.26” (170mm) (57mm) 2.26” 4.0” 6.96” (102mm) (177mm) (57mm) 0.65” (17mm) mounting holes 1/4” - 20NC (4) places not to scale EX-PROOF HOUSING TOP VIEW 2.
Contact for Repairs & Calibration Services The G Series is not designed for user repair and all such work should be done at the factory or under the direct supervision of the Max Technical Service Department. Unauthorized repair work may damage the meter and will void the product warranty. Please make note of model and serial numbers on the flow meter before calling the factory. A return goods authorization number will be issued if the flow meter has to be sent back for repair.