23. TROUBLESHOOTING GUIDE
Before contacting your nearest Max Power distributor, please check the below
troubleshooting guide.
Problem Check
The control panel does not light
up
Check the 6 wire connector behind the joystick
Check the thruster's electronic control box 6 wire
connector
Check the circuit breaker / switch in the boat's
main DC distribution panel
Check the control box's power fuse (8 A)
The relay is clicking but the motor
is not running
Check the motor's power fuse
Check the main battery isolator
Check battery conditions and connections
Check the internal relay contacts
WARNING
Only a qualified technician should check these
points to ensure that the thruster is correctly
reassembled and remains Ignition Protected.
The motor is running but the
thruster is not working
Check the propellers are fitted
Check the motor / drive leg assembly
Check that the tunnel is not obstructed or the
propellors blocked
The thruster lacks power
Check the propellers are fitted
Check the size of the batteries
Check the batteries are sufficiently charged
Check the connections are tightened correctly
Check the power cables sections
(See p. 6 : Recommended cable sections)