23. TROUBLESHOOTING GUIDE
Before contacting your nearest Max Power distributor, please check the below
troubleshooting guide.
Problem Check
The control panel does not light
up
• Check the 6 wire connector behind the joystick
• Check the thruster's electronic control box 6 wire
connector
• Check the circuit breaker / switch in the boat's
main DC distribution panel
• Check the control box's power fuse (8 A)
The relay is clicking but the motor
is not running
•
Check the motor's power fuse
•
Check the main battery isolator
•
Check battery conditions and connections
•
Check the internal relay contacts
WARNING
Only a qualified technician should check these
points to ensure that the thruster is correctly
reassembled and remains Ignition Protected.
The motor is running but the
thruster is not working
• Check the propellers are fitted
• Check the motor / drive leg assembly
• Check that the tunnel is not obstructed or the
propellors blocked
The thruster lacks power
• Check the propellers are fitted
• Check the size of the batteries
• Check the batteries are sufficiently charged
• Check the connections are tightened correctly
•
Check the power cables sections
(See p. 6 : Recommended cable sections)