3.6 POTENTIOMETER ADJUSTMENTS
PITCH OFFSET
This can be done using the VR4 potentiometer on the Configuration Panel. This potentiometer is 
set at the factory so that it has a range of +/-3.75 mm. The midpoint setting should have no effect 
on the label pitch. Turning the potentiometer all the way clockwise should move the print position 
3.75 mm upwards towards the leading edge of the label. Turning the it all the way 
counterclockwise should move the print position down 3.75mm away from the leading edge of 
the label.
1. Place DSW6 on the Configuration Switch in 
the OFF position.
2. Turn the power OFF.
3. While pressing the FEED button on the 
Operator Panel, turn the power ON.
4. When you hear one beep from the printer, 
release the FEED button.
5. Press the LINE button to begin printing 
large Test Labels (press the FEED button 
if you are using labels smaller than 4.1" 
(104 mm) in width).
6. Adjust potentiometer VR4 until the first 
print position is at the desired location on 
the label.
7. Press the FEED button to stop printing. 
Note:  
Adjusting the Label Pitch with VR4 will 
affect the stop position of the label and the 
cut/tear-off positions.
ABCDEFG
ABCDEFG
ABCDEFG
Leading Edge of 
Label as detected 
by the sensor
Moved with 
Positive (+) Offset 
to print on trailing 
edge of label
Must be moved with Minus (-) 
Offset to print on leading edge of 
label
Original First Line 
Print Position
label movement direction