SECTION 5: INTERFACE SPECIFICATIONS
Page 5-4      SATO D508/D512 Operator Manual
5.3 IEEE1284 PARALLEL INTERFACE
The parallel interface for this printer conforms to the IEEE1284 specification. It will 
automatically detect the IEEE1284 signals and operate in the high speed mode. If it does 
not detect the IEEE1284 signals, it will operate in the standard Centronics mode, which 
is significantly slower. For this reason, an interface cable and host interface conforming 
to the IEEE1284 specification must be present to fully utilize the speed capabilities. This 
interface also operates bidirectionally and can report the status of the printer back to the 
host. 
Electrical Specifications
Printer Connector AMP 57-40360 (DDK) or equivalent 
Cable Connector AMP 57-30360 (DDK) or equivalent 
Cable Length 10 ft. (3 m) or less
Signal Level High = +2.4V to +5.0V Low = 0V to -0.4V
 (1)
 Signals required for IEEE1284 mode
PIN   SIGNAL   DIRECTION   PIN   SIGNAL  DIRECTION 
1 STROBE To Printer 19 STROBE Return  Reference 
2 DATA 1  To Printer  20 DATA 1 Return  Reference 
3 DATA 2  To Printer  21 DATA 2 Return  Reference 
4 DATA 3  To Printer  22 DATA 3 Return  Reference 
5 DATA 4  To Printer  23 DATA 4 Return  Reference 
6 DATA 5  To Printer  24 DATA 5 Return  Reference 
7 DATA 6  To Printer  25 DATA 6 Return  Reference 
8 DATA 7  To Printer  26 DATA 7 Return  Reference 
9 DATA 8  To Printer  27 DATA 8 Return  Reference 
10 ACK To Host 28 ACK Return Reference 
11 BUSY To Host 29 BUSY Return Reference 
12 PTR ERROR  To Host  30 PE Return  Reference 
13 SELECT  To Host  31 INIT  From Host 
14 AUTOFD (1)  To Host  32 FAULT  To Host 
15 Not Used  33 Not Used 
16 Logic Gnd  34 Not Used 
17 FG  Frame Ground  35 Not Used   
18 +5V(Z=24Kohm) To Host  36
SELECTIN
 (1)
From Host 