Technical data

HN.50.Y1.02 15
Ramps After signal tuning of points A-D as specified
in the previous figure, the signal follows the
ramp that is specified here. Two sets of ramps
are available for each PVE output (see figure
below). Both work on ramp principle 1, familiar
in the EHR modules. Fast operation can be
obtained by setting Tdown_A and Tdown_B
on zero. The function cannot be used in con-
nec-tion with on/off signals.
Port A (Tup_A, Tdown_ A )
Port B (Tup_B, Tdown_ B )
Units [ms]
Max. (5000, 5000)
Min. (0,0)
Standard (0,0)
Precision 1
2010 HEX (Ramp1 Tup_port A)
2011 HEX (Ramp1 Tdown_port A)
2012 HEX (Ramp1 Tup_port B)
OD index
2013 HEX (Ramp1 Tdown_port B)
2014 HEX (Ramp2 Tup_port A)
2015 HEX (Ramp2 Tdown_port A)
2016 HEX (Ramp2 Tup_port B)
2017 HEX (Ramp2 Tdown_port B)
Ramp switch
Units -
The ramp switch can
be set in four ways:
0: No ramps
1: Ramp 1 used
permanently
2: Ramp 2 used
permanently
[ ]: Switch between ramp 1
and ramp 2 using an on/off
signal.
If this is the case, the
address of the on/off (OD
index 2100-2103) must be
entered in this field.
Max. 3 sec.
Min. 0
Standard 0
Precision 1
OD index 2019 HEX
Used to select the active ramp setting for a
PVG CIP output.
Port B
Port B
Port A
Port A