Technical data

HN.50.Y1.02 5
Supply voltage U
dc
10 - 30 V DC
Max. supply voltage 36 V DC
Max. pulsation (peak to peak) 5%
Common to PVG CIP &
Prof 1 CIP
Power supply
Baud rate 10 Kbit/s - 1000 Kbit/s
Communication profile CANopen ver. 3.0
Typical start-up time < 500 ms
CAN Full CAN
CAN interface - ISO 11898 ver. 2.0 B
Emission EN 50081-2
Immunity EN 50082-2
HF immunity
ISO 14892 (60 V/m, 20 MHz - 1000 MHz)
ISO 13766 (60 V/m, 20 MHz - 1000 MHz)
EMC - EMC Directive (89/336/ECC)
Ambient temperature
Storage temperature -40°C to +90°C
Operating temperature -30°C to +70°C
Environmental data
Technical data
Prof 1 CIP
CAN_TERM Pin 1
CAN+ Pin 4
PVG CIP
CAN_TERM Pin 16
CAN+ Pin 3
Termination
A CAN bus must be terminated at both ends
where CAN+ and CAN- are to be connected
via a 120 resistor.
The CIP Configuration Tool is a program
developed for setting up systems consisting of
PVG CIP and Prof 1 CIP.
CIP Configuration Tool
Termination can be effected by connecting a
jumper between the pins given below (a 120
resistor is fitted in the component).
ISO 11898
Vehicles, interchange of digital information - Controller Area
Network (CAN) for high-speed communication
CANopen communication profile for industrial systems, CiA
CANopen standard draft 3.0
Revision 3.0
EMC Directive 89/336/ECC
ISO 14892 Agricultural and forestry machines - electromagnetic compatibility
ISO 13766 Earth-moving machinery - electromagnetic compatibility
References
Name
Code no.
Description
155U....
CIP Configuration Tool 5670 Product contents
CIP Configuration Tool
CIP Downloading Utility
CANview
CAN dongle
Documentation, examples, help files