User's Manual

34
RIOTRONIC X+
User Manual
Choosing the active pattern is the first thing after turning the Logger on. It can be chosen
from the list or user can create a new one. Selected pattern have to be confirmed with OK or
F2 button.
To create a new pattern * NEW PATTERN * item should be chosen from the end of the list.
The name of the new metric can be maximal 8 letters long. There can be up to 100 patterns
stored in the Logger.
Active pattern name is shown in second line at the top of the display.
6.3. Programming detonators
Programming the detonators is the main function of the Logger. As soon as the active
pattern is chosen, Logger goes to programming the next detonator.
Programming detonators can look different depending on chosen connection mode and
delay mode.
Connection mode can be:
One by one (1 x 1) – in this mode only one detonator can be connected to the Logger.
Bus (||)in this mode Logger is connected to the bus-line and every next detonator
is connected to this bus together with all detonators connected previously.
NFC (NFC) – in this mode detonator’s ID is read from RFID tag.
Delay mode can be:
Manual (M) – delay time for each detonator have to be entered manually.
Incremental (++) delay time for each detonator is suggested according to
increments defined for pattern.
No delay (#) – only detonator’s ID is read, delay time have to set up later.
PC (PC) for patterns created by PC software delay time for each detonator is
suggested according to pattern file.
Connection mode and delay mode can be changed in settings menu.
6.3.1. Manual mode
Figure 31. Manual programming screen
Detonator’s number in pattern with logger’s ID letter
Delay time