50
RIOTRONIC X+
User Manual
When receiving is finished, another pattern can be transferred and combined in one blast.
Figure 49. Pattern received
If there are no other patterns to transfer blast summary will be displayed. Name of the blast
can be changed there.
Figure 50. Blast summary
7.2.10. Test blast
Before blast can be initiated firing line have to checked. First, all detonators from transferred
patterns are checked if they are connected to the line and programmed with correct delay
time. If the delay time is wrong, Blaster tries to reprogram them. At the end Blaster search
for extra detonators connected to the firing line. Detonators can be counted to one of
following categories:
OK – detonator is present and programmed with correct delay time,
MISSING – detonator is not connected to firing line,
ERROR – detonator is connected, but cannot be programmed with correct delay time,
EXTRA – additional detonator connected to firing line.